Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

 

 

 

217-XXX-000

Failed BIOS hard disk drive

Hard disk drive 1

 

test

 

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array.

 

 

 

 

217-XXX-001

Failed BIOS hard disk drive

Hard disk drive 2

 

test

 

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array.

 

 

 

 

217-XXX-002

Failed BIOS hard disk drive

Hard disk drive 3

 

test.

 

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array

 

 

 

 

217-XXX-003

Failed BIOS hard disk drive

Hard disk drive 4

 

test

 

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array.

 

 

 

 

217-XXX-004

Failed BIOS hard disk drive

Hard disk drive 5

 

test

 

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array.

 

 

 

 

217-XXX-005

Failed BIOS Fixed Disk test

Hard disk drive 6

 

Note: If RAID is configured,

 

 

the hard disk drive number

 

 

refers to the RAID logical

 

 

array.

 

 

 

 

264-XXX-0NN

Failed tape-drive test

1. Tape cartridge, if user executed the read/write tape

 

 

 

 

drive test (XXX = 256)

 

 

2. SCSI or power cable connected to tape drive with SCSI ID

 

 

NN.

 

 

3. Tape drive with SCSI ID NN (Refer to the Help and

 

 

Service Information appendix of the tape drive’s user

 

 

guide).

 

 

4. System board or SCSI Controller (Run SCSI controller

 

 

diagnostic to determine if the SCSI bus is functioning

 

 

correctly.)

 

 

 

264-XXX-999

Errors on multiple tape drives

See error messages/text in the PC Doctor error log for

 

 

detailed information on each individual tape drive error.

 

 

 

301-XXX-000

Failed Keyboard test

Keyboard

 

 

 

405-XXX-000

Failed Ethernet test on

1. Verify that Ethernet is not disabled in BIOS

 

controller on the system

 

2. System board

 

board

 

 

 

 

 

104NAS 200 User’s Reference

Page 116
Image 116