IBM 201 Troubleshooting the ServeRAID-4Lx and 4H, Testing the Quad-Port 10/100 Ethernet adapter

Models: 201

1 140
Download 140 pages 39.72 Kb
Page 82
Image 82

Table 11. Alacritech Quad-Port 10/100 Ethernet adapter LED definitions

LED

Indication

Meaning

 

 

 

LNK

Off

Either the adapter or the switch (or both)

 

 

are not receiving power, or the cable

 

 

connection between them is faulty.

 

 

 

 

Green

The adapter and switch are receiving

 

 

power. The cable connection between

 

 

them is good. A 100 Mbps link has been

 

 

established.

 

 

 

 

Amber

The adapter and switch are receiving

 

 

power. The cable connection between

 

 

them is good. A 10 Mbps link has been

 

 

established.

 

 

 

ACT

Off

The adapter is not sending or receiving

 

 

network data.

 

 

 

 

Flashing amber

The adapter is sending or receiving

 

 

network data.

 

 

 

Testing the Quad-Port 10/100 Ethernet adapter

The event log tells you when you should run diagnostics. You can view the event log from the Event Viewer located in the Administrative Tools folder on the Start Menu, located under Programs. When the event log reports that “SLICx has determined that the adapter is not functioning properly,” you can run diagnostics on the Quad-Port 10/100 Ethernet adapter using the following procedure:

1.Run the SLICuser application from the Start Menu, located under the Program Files folder in the Alacritech Folder.

2.Select the Diagnostics tab.

Note: Running diagnostics disrupts all ports of the adapter.

3.Click Run. The adapter will then run through a self-test of the IPP and the selected port of the adapter. A properly functioning board will display a window in which all of its tests have Passed.

4.Close the SLICuser utility by clicking OK.

Troubleshooting the ServeRAID-4Lx and 4H

Error codes and messages display on the screen in a line of text immediately after the adapter BIOS version.

If POST detects changes in the controller configuration or detects a controller hardware problem, messages appear on the screen. Refer to “POST (ISPR) error procedures” on page 71 and correct the problem.

If there is no POST Error or Configuration Error message, the BIOS screen messages resemble the sample shown below. Note that your version may be different from the one shown.