Table 18. Diagnostic error messages (continued)

Error Code

Meaning

FRU/action

 

 

 

014-XXX-000

Failed Parallel Port test

System board

 

 

 

015-XXX-001

Failed USB test

System board

 

 

 

 

015-XXX-015

Failed USB external loopback

1.

Make sure parallel port is not disabled

 

test

2.

Re-run USB external loopback test

 

 

 

 

3.

System board

 

 

 

 

015-XXX-198

USB device connected

1.

Remove USB devices from USB1 and USB2

 

during the USB test

 

2.

Re-run USB external loopback test

 

 

 

 

3.

System board

 

 

 

020-XXX-000

Failed PCI Interface test

System board

 

 

 

 

020-XXX-001

Failed Hot-Swap Slot 1 PCI

1.

PCI hot-swap latch assembly

 

Latch test.

 

2.

System board

 

 

 

 

 

 

020-XXX-002

Failed hot-swap slot 2 PCI

1.

PCI hot-swap latch assembly

 

latch test

 

2.

System board

 

 

 

 

 

 

020-XXX-003

Failed hot-swap slot 3 PCI

1.

PCI hot-swap latch assembly

 

latch test

 

2.

System board

 

 

 

 

 

 

020-XXX-004

Failed hot-swap slot 4 PCI

1.

PCI hot-swap latch assembly

 

latch test

 

2.

System board

 

 

 

 

 

030-XXX-000

Failed internal SCSI interface

System board

 

test

 

 

 

 

 

035-XXX-099

No adapters were found

If the adapter is installed, recheck the connection.

 

 

 

035-XXX-S99

Failed RAID test on PCI slot

Note: Check the System Error Log before replacing a part.

 

S

1.

Adapter

 

 

 

 

2.

SCSI backplane

 

 

3.

Cable

 

 

 

035-XXX-SNN

NN = SCSI ID of failing hard

Note: Check the System Error Log before replacing a

 

disk

part.Hard disk drive with SCSI ID NN on RAID adapter in

 

 

PCI slot S.

 

 

 

 

035-253-S99

RAID adapter initialization

1.

Obtain the basic and extended configuration status

 

failure; ServeRAID Adapter in

 

 

and refer to the ServeRAID Hardware Maintenance

 

slot S is not configured

 

 

 

Manual for more information

 

properly

 

 

2.

Adapter

 

 

 

 

3.

SCSI backplane

 

 

4.

Cable

 

 

 

075-XXX-000

Failed power supply test

Power supply

 

 

 

 

089-XXX-001

Failed microprocessor test

1.

VRM 1 for microprocessor 1

 

 

 

 

2.

Microprocessor 1

 

 

 

 

089-XXX-002

Failed test for optional

1.

VRM 2

 

microprocessor

 

2.

Optional microprocessor 2

 

 

 

 

 

 

166-250-000

System Management failed:

1.

Reseat the I2C cables between Remote Supervisor

 

(I2C cable is disconnected.

 

 

Adapter (in PCI slot 1/J44) and system board (J45)

 

Reconnect I2C cable

 

 

2.

I2C cables

 

between Remote Supervisor

 

 

 

 

Adapter and system board.)

 

 

 

 

 

 

Appendix C. Engine POST messages 101

Page 113
Image 113
IBM 201 manual Error Code