Pressing Enter upon completion of the activity setup will start the search and launch the Search Results window. See section 5.4 for operating instructions.

5.4 Search Filters

Pressing the Search button a third time brings up the Search Filters Menu. Use the Search Filters menu to specify:

The type of operation to be performed: Play from Disk, Play from Archive, Copy from Disk to Archive, and Copy from Archive to Disk.

The Start and Stop date of the search.

The Start and Stop time of the search.

Searching for recorded activity, events, retail text, or alarms.

Searching for a text string.

Which cameras to search inclusively or exclusively.

Search Filters

Operation:

DATE (MM/DD/YY)

TIME (HH:MM)

Start

Stop

Start

Stop

01/27/04

01/27/04

20:57

20:59

 

 

 

 

Activity

Event Alarm

Text

 

X

Retail

X

Camera

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

XXXXXXXXXXXXXXXX

[CANCEL]

EDIT MODE

[START SEARCH]

 

 

 

 

Hit

‘ZOOM’ to edit retail text list

 

Hit

‘ENTER’ to toggle EDIT Mode

 

The following options are available when an archive device is connected:

1.Play from Disk.

2.Play from Archive.

3.Copy from Disk to Archive.

4.Copy from Archive to Disk.

Selecting these functions displays thumbnails in the Search Results window.

To access the Retail Search Menu select ‘RETAIL’

and press the ‘ZOOM’ key.

Hit Camera buttons to select/deselect individual cameras. Use the Zoom button to globally select/deselect cameras to search.

Selecting Search Parameters

1.Rotating the Jog to navigate, highlight the box adjacent to the parameters that you wish to modify.

2.Once in the Parameter Box, use the Shuttle to navigate through the fields and the Jog to change the values.

3.To activate the parameter, use the Shuttle or the Enter button to place an [X] in the check box.

4.When finished, use the Jog to navigate to another parameter.

0150-0193G

73

DVMRe Triplex

Image 73
Contents DVMRe Triplex 0150-0193G / April Contents RS232 Remote Control Protocol AlarmsSearching WebBrowser10Macro Tables 11Warranty and ServiceFeatures Products Featured In This ManualDVMRe Triplex Overview Product DescriptionDefault Passwords Four-Channel Units PasswordsPackage Contents Installation EnvironmentUnpacking Ten and Sixteen-Channel UnitsBack Panel Associated EquipmentCamera Inputs Alarm I/O PortComposite Monitor Output Monitor OutputAlarm PCB Alarm InputNormally Open and Normally Closed Connections External Alarm Acknowledge Input Alarm Relay OutputAUX Port Voltage 30V MaxRJ-45 Pin Configuration For RS485 Port RS485 ConnectorEthernet Port Ieee 1394 Firewire Port RJ-45 Pin Configuration For Ethernet PortScsi Port Gender on unit FemaleDB-9 Pin Configuration For Port Power-UpRJ-45 Pin Configuration For RS232 Port RS232 PortPower-up procedure Minimum Recommended Menu SetupCheck Video Input Quality Check Record And Playback QualityPrincipal Operating Modes DMVRe Triplex Basic OperationsFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Searching Recorded Data Stop PlaybackStop Button Sequence Button Number ButtonMonitor Displays During Recording RecordingRecord Button Display Options Entering Active Cameo ModeActive Cameos Available Multiscreen DisplaysSequencing Returning To The Default Sequence ListSelecting Cameras Dwell TimeChanging Position And Color Of Title And Status Indicators On-screen IndicatorsStatus Indicators Sequencing In CameosConditional Indicators Triplex ModeStatus Display Box ATM/POS Text DisplayReverse Play Button Jog / Shuttle Freeze Button Stop Button StopNumber Button Sequence Button Print Image FeatureZoom and Function Button Equipment Printer SetupConditions Menu System Overview Accessing The Menu SystemMenu Notation In This Manual Available MenusNavigating The Menu System Menus In This ManualMenu Shortcuts Opening the Drop Down Menus Rotate the JogTime/Date Main MenuMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Main Menu → Time/Date → Set Date FormatMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupMain Menu → Sequencing → Multiscreen Dwell RecordMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Event Settings Main Menu → Record → Record TimerMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateMain Menu → Record → Alarm Record Rate Main Menu → Record → Disk Maintenance Main Menu → Record → Record ModeDisk Test Setup Menu No OverwriteMain Menu → Record → Record Lock DisableMain Menu → Record → Auto Delete Mode AlarmsMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm LatchMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Notification Email Notification SetupEnable TCP/IP Notification SetupMacro Main Menu → Alarms → Archive AlarmsMain Menu → Macro → Macro Record Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesMain Menu → Macro → Edit Submacro Motion DetectionRunning a Macro Daylight Savings Time Alternate MethodIndividual Enable Menu Main Menu → Motion Detection → Enable/Disable DetectionMain Menu → Motion Detection → Setup Parameters Activity Detection SetupMain Menu → Motion Detection → Setup Active Zones Intrusion Detection SetupActivity Grid Setup Screen Main Menu → Camera Setup → Camera Titles Camera SetupSensitivity Scope Main Menu → Motion Detection → Indicate DetectionTitles Display Main Menu → Camera Setup → AGCEdit Titles Camera Title Edit MenuIndividual Disable Main Menu → Camera Setup → Camera DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → MonB Svhs Main Menu → Camera Setup → Camera ScopeLuminance Histogram Audio Setup Archive SetupCommunications Pots SetupMain Menu → Communications → RS232 PortMain Menu → Communications → RS485 Baud RateMain Menu → Communications → Ethernet Settings Return To Factory Defaults Factory SettingsFront Panel Lock Change LanguageEthernet Password Changing the Installer or Operator PasswordsActivate The Ethernet Password Deactivate The Ethernet PasswordQuickInstall Menu Overview QuickInstall MenuQuickInstall Menu Item Primary Menu Location Section Manual Operator MenuSystemView Menu Overview SystemView MenuOperator Menu Item Primary Menu Location Section Manual View Screen View ScreensRecord Rate Record Timer∙ Event Associated Cameras Up to ∙ On/Off On or Off∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Network Address∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Http Port 80Alarm Input AlarmsAlarm Output Alarm AcknowledgeMonitor-B Display During Alarm Alarm Operations During PlaybackLive Alarms Displays Channel UnitsSearching For Recorded Alarms Alarm History BoxRecorded Alarms Search Menu Overview SearchingQuick Archive to CD Disk Analysis ScreenSearch Button Function Button Motion SearchSelecting Search Parameters Search FiltersText File Format Retail SearchUploading/Downloading the retailsearch .txt File Date MM/DD/YY Time Hhmm Local Retail Search ScreenRestrictions and Limitations Search ResultsActivate Search Activity, Text, Motion, Alarm Search Results WebBrowser To access the web interfaceMain Viewing Area WaveBrowser Overview and Controls∙ The Main Viewing Area The large blue area Button Panel Drop Down Volume List BoxFunctionality DVMRe Triplex WaveLinkName Code Description Example Email Links General Technical SpecificationsConnections VideoMotion Detection AudioPart Numbers Message Type Message StructureAlarm Actions Alarm/Event FieldsNo Event Change 0000 0000b Event ActionsStart Event 0000 0001b Stop Event 0000 0010bData Structure Front Panel Button EmulationDescription Data structure Configuration and StatusMacro Functions Table Macro TablesMacro Description Number Event Day Time Macro to Run Scheduled Macro TableFactory Service Warranty and ServiceFactory Address Advance Replacement Policy Warranty and Return Information0150-0193G