GE 0150-0193G manual Motion Search, Function Button

Page 72

5.3 Motion Search

Pressing the Search button a second time will bring up the Motion Search menu. This menu performs a motion search with six preset time parameters and a custom search option. Rotate the Jog to navigate and the Shuttle to select a specific parameter. Selecting the Custom option and pressing the Enter button starts playback and brings up another window with Start/Stop, Time/Date options. These options provide the parameters to focus the search to a specific time period.

Motion Search

Last 2hrs

Last 8hrs

Last day

Last 7 days

Last 4 weeks

Last 12 weeks

X Custom

Selecting any of the other options and pressing Enter starts playback and displays the Motion Search Setup Screen.

5

This screen overlays the current playback video and allows the user to enable or disable motion detection on the screen within blocks that form a 16 x 16 grid.

Pressing the Function key while in this screen overlays a help screen with all the available commands.

{F}

Function

Button

‘MENU’ : Exit Activity Setup

‘ENTER’: Save and Exit Activity Setup

‘PAUSE’: Toggle between Enable and Neutral

‘STOP’ : Toggle between Disable and Neutral

‘ZOOM’ : Disable/Enable all zones

0150-0193G

72

DVMRe Triplex

Image 72
Contents DVMRe Triplex 0150-0193G / April Contents Alarms RS232 Remote Control ProtocolSearching WebBrowser11Warranty and Service 10Macro TablesProducts Featured In This Manual FeaturesDVMRe Triplex Overview Product DescriptionPasswords Default Passwords Four-Channel UnitsInstallation Environment Package ContentsUnpacking Ten and Sixteen-Channel UnitsAssociated Equipment Back PanelAlarm I/O Port Camera InputsComposite Monitor Output Monitor OutputAlarm Input Alarm PCBNormally Open and Normally Closed Connections Alarm Relay Output External Alarm Acknowledge InputAUX Port Voltage 30V MaxRS485 Connector RJ-45 Pin Configuration For RS485 PortEthernet Port RJ-45 Pin Configuration For Ethernet Port Ieee 1394 Firewire PortScsi Port Gender on unit FemalePower-Up DB-9 Pin Configuration For PortRJ-45 Pin Configuration For RS232 Port RS232 PortMinimum Recommended Menu Setup Power-up procedureCheck Video Input Quality Check Record And Playback QualityDMVRe Triplex Basic Operations Principal Operating ModesFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Stop Playback Searching Recorded DataStop Button Sequence Button Number ButtonRecording Monitor Displays During RecordingRecord Button Entering Active Cameo Mode Display OptionsActive Cameos Available Multiscreen DisplaysReturning To The Default Sequence List SequencingSelecting Cameras Dwell TimeOn-screen Indicators Changing Position And Color Of Title And Status IndicatorsStatus Indicators Sequencing In CameosTriplex Mode Conditional IndicatorsStatus Display Box ATM/POS Text DisplayStop Reverse Play Button Jog / Shuttle Freeze Button Stop ButtonPrint Image Feature Number Button Sequence ButtonZoom and Function Button Printer Setup EquipmentConditions Accessing The Menu System Menu System OverviewMenu Notation In This Manual Available MenusMenus In This Manual Navigating The Menu SystemMenu Shortcuts Opening the Drop Down Menus Rotate the JogMain Menu Time/DateMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Format Main Menu → Time/Date → Set DateMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Network Time Setup Main Menu → Time/Date → Set RegionRecord Main Menu → Sequencing → Multiscreen DwellMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Record Timer Main Menu → Record → Event SettingsMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededMain Menu → Record → Timelapse Record Rate Camera 1 0.40 pps 2.5 sppMain Menu → Record → Event Record Rate Main Menu → Record → Activity Record RateMain Menu → Record → Alarm Record Rate Main Menu → Record → Record Mode Main Menu → Record → Disk MaintenanceDisk Test Setup Menu No OverwriteDisable Main Menu → Record → Record LockAlarms Main Menu → Record → Auto Delete ModeMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Latch Main Menu → Alarms → Alarm ActionMain Menu → Alarms → Alarm Record Mode Main Menu → Alarms → Enable / DisableMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Link To a Macro Main Menu → Alarms → Fullscreen AlarmMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Videoloss Action Main Menu → Alarms → Pre Alarm DurationMain Menu → Alarms → Notification Email Notification SetupTCP/IP Notification Setup EnableMain Menu → Alarms → Archive Alarms MacroMain Menu → Macro → Macro Record Macro Excluded Features Main Menu → Macro → Timed Macro StartMotion Detection Main Menu → Macro → Edit SubmacroRunning a Macro Daylight Savings Time Alternate MethodMain Menu → Motion Detection → Enable/Disable Detection Individual Enable MenuMain Menu → Motion Detection → Setup Parameters Activity Detection SetupIntrusion Detection Setup Main Menu → Motion Detection → Setup Active ZonesActivity Grid Setup Screen Camera Setup Main Menu → Camera Setup → Camera TitlesSensitivity Scope Main Menu → Motion Detection → Indicate DetectionMain Menu → Camera Setup → AGC Titles DisplayEdit Titles Camera Title Edit MenuMain Menu → Camera Setup → Camera Disable Individual DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → Camera Scope Main Menu → Camera Setup → MonB SvhsLuminance Histogram Archive Setup Audio SetupPots Setup CommunicationsMain Menu → Communications → RS232 PortBaud Rate Main Menu → Communications → RS485Main Menu → Communications → Ethernet Settings Factory Settings Return To Factory DefaultsFront Panel Lock Change LanguageChanging the Installer or Operator Passwords Ethernet PasswordActivate The Ethernet Password Deactivate The Ethernet PasswordQuickInstall Menu QuickInstall Menu OverviewQuickInstall Menu Item Primary Menu Location Section Manual Operator MenuSystemView Menu SystemView Menu OverviewOperator Menu Item Primary Menu Location Section Manual View Screens View ScreenRecord Timer Record Rate∙ Event Associated Cameras Up to ∙ On/Off On or Off∙ Network Address ∙ Keyboard Lock On or Off ∙ Record Lock On or Off∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Http Port 80Alarms Alarm InputAlarm Output Alarm AcknowledgeAlarm Operations During Playback Monitor-B Display During AlarmLive Alarms Displays Channel Units Alarm History Box Searching For Recorded Alarms Recorded Alarms Searching Search Menu OverviewDisk Analysis Screen Quick Archive to CDSearch Button Motion Search Function ButtonSearch Filters Selecting Search ParametersRetail Search Text File FormatUploading/Downloading the retailsearch .txt File Local Retail Search Screen Date MM/DD/YY Time HhmmSearch Results Restrictions and LimitationsActivate Search Activity, Text, Motion, Alarm Search Results To access the web interface WebBrowserWaveBrowser Overview and Controls Main Viewing Area∙ The Main Viewing Area The large blue area Drop Down Volume List Box Button PanelDVMRe Triplex WaveLink FunctionalityName Code Description Example Email Links Technical Specifications GeneralConnections VideoAudio Motion DetectionPart Numbers Message Structure Message TypeAlarm/Event Fields Alarm ActionsEvent Actions No Event Change 0000 0000bStart Event 0000 0001b Stop Event 0000 0010bFront Panel Button Emulation Data StructureDescription Configuration and Status Data structureMacro Tables Macro Functions TableMacro Description Number Scheduled Macro Table Event Day Time Macro to RunWarranty and Service Factory ServiceFactory Address Warranty and Return Information Advance Replacement Policy0150-0193G