GE 0150-0193G Main Menu → Alarms → Videoloss Action, Main Menu → Alarms → Pre Alarm Duration

Page 45

qMain Menu Alarms Videoloss Action

Use this menu to configure how the unit responds to videoloss.

Camera: Select the camera you wish to configure.

Relay 1: If enabled, the unit will activate Relay 1 when videoloss is detected.

Relay 2: If enabled, the unit will activate Relay 2 when videoloss is detected.

Buzzer: Use this setting to disable the videoloss buzzer activation on a per camera basis. To disable videoloss buzzer activation on all cameras go to the Main Menu Alarms Buzzer Setup menu, described in the previous section.

Videoloss Action

Camera :

01

Relay

1:

Disable

Relay

2:

Enable

Buzzer :

Enable

[CANCEL]

[OK]

qMain Menu Alarms Pre Alarm Duration

During recording, the unit stores up to 5 seconds of recorded information in a buffer. This data can be automatically retrieved when an alarm is activated. Select the amount of time just previous to the activation of an alarm you wish to retrieve.

Pre Alarm Duration

(Time in Seconds)

05

qMain Menu Alarms Notification

Use this menu to select:

Email

Email Alarm Notification.

TCP/IP

TCP/IP Notification.

Email Notification Setup

This screen allows the user to setup the types of events to be notified of, and the email addresses (up to two) to be notified. Follow the context sensitive on-screen instructions to setup the individual fields. Also, please note that the Region/Time Zone setting must be set correctly for Email notification to time stamp messages accurately.

0150-0193G

45

DVMRe Triplex

Image 45
Contents DVMRe Triplex 0150-0193G / April Contents RS232 Remote Control Protocol AlarmsSearching WebBrowser10Macro Tables 11Warranty and ServiceFeatures Products Featured In This ManualDVMRe Triplex Overview Product DescriptionDefault Passwords Four-Channel Units PasswordsPackage Contents Installation EnvironmentUnpacking Ten and Sixteen-Channel UnitsBack Panel Associated EquipmentCamera Inputs Alarm I/O PortComposite Monitor Output Monitor OutputAlarm Input Alarm PCBNormally Open and Normally Closed Connections External Alarm Acknowledge Input Alarm Relay OutputAUX Port Voltage 30V MaxRS485 Connector RJ-45 Pin Configuration For RS485 PortEthernet Port Ieee 1394 Firewire Port RJ-45 Pin Configuration For Ethernet PortScsi Port Gender on unit FemaleDB-9 Pin Configuration For Port Power-UpRJ-45 Pin Configuration For RS232 Port RS232 PortPower-up procedure Minimum Recommended Menu SetupCheck Video Input Quality Check Record And Playback QualityPrincipal Operating Modes DMVRe Triplex Basic OperationsFront Panel Play Forward Button Begins PlaybackLive Viewing Playback Searching Recorded Data Stop PlaybackStop Button Sequence Button Number ButtonRecording Monitor Displays During RecordingRecord Button Display Options Entering Active Cameo ModeActive Cameos Available Multiscreen DisplaysSequencing Returning To The Default Sequence ListSelecting Cameras Dwell TimeChanging Position And Color Of Title And Status Indicators On-screen IndicatorsStatus Indicators Sequencing In CameosConditional Indicators Triplex ModeStatus Display Box ATM/POS Text DisplayReverse Play Button Jog / Shuttle Freeze Button Stop Button StopPrint Image Feature Number Button Sequence ButtonZoom and Function Button Printer Setup EquipmentConditions Menu System Overview Accessing The Menu SystemMenu Notation In This Manual Available MenusNavigating The Menu System Menus In This ManualMenu Shortcuts Opening the Drop Down Menus Rotate the JogTime/Date Main MenuMain Menu Overview Main Menu → Time/Date → Time / Date DisplayMain Menu → Time/Date → Set Date Format Main Menu → Time/Date → Set DateMain Menu → Time/Date → Set Master / Slave Main Menu → Time/Date → Set Region Main Menu → Time/Date → Network Time SetupRecord Main Menu → Sequencing → Multiscreen DwellMain Menu → Sequencing → Fullscreen Dwell Main Menu → Record → Event Settings Main Menu → Record → Record TimerMain Menu → Record → Record Quality Record Quality Picture Quality Disk Space NeededCamera 1 0.40 pps 2.5 spp Main Menu → Record → Timelapse Record RateMain Menu → Record → Activity Record Rate Main Menu → Record → Event Record RateMain Menu → Record → Alarm Record Rate Main Menu → Record → Disk Maintenance Main Menu → Record → Record ModeDisk Test Setup Menu No OverwriteMain Menu → Record → Record Lock DisableMain Menu → Record → Auto Delete Mode AlarmsMain Menu → Alarms → Input Configuration Should not be the only alarm device on siteMain Menu → Alarms → Alarm Action Main Menu → Alarms → Alarm LatchMain Menu → Alarms → Enable / Disable Main Menu → Alarms → Alarm Record ModeMain Menu → Alarms → Alarm History ∙ Enable All ∙ Disable AllMain Menu → Alarms → Fullscreen Alarm Main Menu → Alarms → Link To a MacroMain Menu → Alarms → Relay Configuration Main Menu → Alarms → Buzzer SetupMain Menu → Alarms → Pre Alarm Duration Main Menu → Alarms → Videoloss ActionMain Menu → Alarms → Notification Email Notification SetupEnable TCP/IP Notification SetupMain Menu → Alarms → Archive Alarms MacroMain Menu → Macro → Macro Record Main Menu → Macro → Timed Macro Start Macro Excluded FeaturesMain Menu → Macro → Edit Submacro Motion DetectionRunning a Macro Daylight Savings Time Alternate MethodIndividual Enable Menu Main Menu → Motion Detection → Enable/Disable DetectionMain Menu → Motion Detection → Setup Parameters Activity Detection SetupIntrusion Detection Setup Main Menu → Motion Detection → Setup Active ZonesActivity Grid Setup Screen Main Menu → Camera Setup → Camera Titles Camera SetupSensitivity Scope Main Menu → Motion Detection → Indicate DetectionTitles Display Main Menu → Camera Setup → AGCEdit Titles Camera Title Edit MenuIndividual Disable Main Menu → Camera Setup → Camera DisablePower Up Disable Auto Disable NowMain Menu → Camera Setup → Camera Scope Main Menu → Camera Setup → MonB SvhsLuminance Histogram Audio Setup Archive SetupCommunications Pots SetupMain Menu → Communications → RS232 PortMain Menu → Communications → RS485 Baud RateMain Menu → Communications → Ethernet Settings Return To Factory Defaults Factory SettingsFront Panel Lock Change LanguageEthernet Password Changing the Installer or Operator PasswordsActivate The Ethernet Password Deactivate The Ethernet PasswordQuickInstall Menu Overview QuickInstall MenuQuickInstall Menu Item Primary Menu Location Section Manual Operator MenuSystemView Menu SystemView Menu OverviewOperator Menu Item Primary Menu Location Section Manual View Screen View ScreensRecord Rate Record Timer∙ Event Associated Cameras Up to ∙ On/Off On or Off∙ Keyboard Lock On or Off ∙ Record Lock On or Off ∙ Network Address∙ Time Zone GMT+0000 ∙ QuickWave CD Write On or Off ∙ Http Port 80Alarm Input AlarmsAlarm Output Alarm AcknowledgeMonitor-B Display During Alarm Alarm Operations During PlaybackLive Alarms Displays Channel UnitsAlarm History Box Searching For Recorded AlarmsRecorded Alarms Search Menu Overview SearchingDisk Analysis Screen Quick Archive to CDSearch Button Function Button Motion SearchSelecting Search Parameters Search FiltersRetail Search Text File FormatUploading/Downloading the retailsearch .txt File Date MM/DD/YY Time Hhmm Local Retail Search ScreenSearch Results Restrictions and LimitationsActivate Search Activity, Text, Motion, Alarm Search Results WebBrowser To access the web interfaceWaveBrowser Overview and Controls Main Viewing Area∙ The Main Viewing Area The large blue area Button Panel Drop Down Volume List BoxDVMRe Triplex WaveLink FunctionalityName Code Description Example Email Links General Technical SpecificationsConnections VideoAudio Motion DetectionPart Numbers Message Type Message StructureAlarm Actions Alarm/Event FieldsNo Event Change 0000 0000b Event ActionsStart Event 0000 0001b Stop Event 0000 0010bFront Panel Button Emulation Data StructureDescription Data structure Configuration and StatusMacro Tables Macro Functions TableMacro Description Number Event Day Time Macro to Run Scheduled Macro TableWarranty and Service Factory ServiceFactory Address Advance Replacement Policy Warranty and Return Information0150-0193G