7.1 PROGRAM SELECTION

The DSP 244 offers 30 user-definable program presets (U01 - U30) and up to 50 factory pre-programmed presets (F01-F50). Altogether you have the possibility to choose from this selection of up to 80 different programs.

CAUTION: A program also defines the configuration and therefore also assignment of the inputs and outputs of the DSP 244. When changing a program you have to keep in mind that also the wiring has to be changed, if for instance a Low-range output becomes a High-range output. Thus, an according message appears on the display, every time a program change is performed that also includes a change of the momentary configuration.

1.After pressing the RECALL key (9) you are located in the program selection menu.

2.For selecting the desired program preset you can either use the rotary encoder (10) or the SELECT keys (5) and (6). The display instantaneously shows the new program name and the according configuration.

3.Activate the program by pressing the RECALL key (9). A safety dialog appears, asking you if you really want to activate the selected program. In case the new program’s configuration differs from the one that had been previously selected, an additional dialog on the display informs you about this circumstance and about the possibility to probably change the wiring to prevent faulty operation and the connected loudspeaker systems from being damaged.

4.By pressing the RECALL key (9) again, the program selection is being acknowledged. Pressing any other key cancels the selection. Depending on your action, either the new program is activated or the previous program stays in memory.

7.2 EDITING

The EDIT menu allows you to change the setting of parameters. A detailed description of all possible settings is provided in chapter 8, PARAMETERS. The selection of accessible parameters depends on the actual EDIT mode. For further information, please refer to chapter 9.5, OPERATION MODE SELECTION.

1.Press the EDIT key (4).

2.You are located in the Edit menu. The display shows either the first menu-page of the active

program or the last page that you made changes to, including all accessible parameters. A menu-page always consists of the channel (IN1, IN2, IN1+2, OUT1, OUT2, OUT3, OUT4), the function block (EQ, X-OVER, DELAY, ROUTING, LEVEL, etc.), and the corresponding parameters (e. g. Type, f, Q, Gain in case of an EQ). The momentary selected function block or parameter is marked by a black line.

7-2

Image 19
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionControls and Connections Controls and ConnectionsFront Panel 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartDelay Alignment Over SettingsLoudspeaker Equalization Matching the Frequency Response Compressor / Limiter SettingsConfigurations of the DSP Configurations of the DSPFull Edit Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NCompressor and Limiter Threshold Unit VU Level Meter Display ModeEdit Protection Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Technical Specifications SpecificationsPeci F I C a T IO N S Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty