Dynacord DSP 244 owner manual Controls and Connections, Front Panel

Page 5

CONTROLS AND CONNECTIONS

2. CONTROLS AND CONNECTIONS

2.1 FRONT PANEL

1, Control INPUT 1 / INPUT 2

Rotary controls to set the input levels of the inputs 1 and 2 of the DSP 244.

The input signal can be amplified by up to 6 dB (control set to its clockwise margin) or attenuated by any degree. Set the level as high as possible without clipping to achieve the highest possible S/N ratio. Checking your settings is possible via the reading of the two level meter instruments.

2, Level meters

The level meter instruments are meant for optical monitoring of the input signal levels, individually showing the peak value of the correspondent input signal. The input control should be set to a position so that the meter instruments indicate a level between -6 and -12 dB. To prevent internal clipping, make sure that the clip-LEDs are not lit. Two different indication modes can be selected: “Peak Hold”-function or “Slow Mode”.

3, Graphic display

In the PLAY mode this 122 x 32 dots LC-display shows the name of the program, its number, name and description of the chosen loudspeaker systems, as well as the momentary active configuration. In EDIT mode the display shows the function blocks including their individual parameters and parameter values. Additionally and depending on the actually chosen mode, the display also indicates option menus, status messages, short operational notes, etc.

4, EDIT-key

This key allows to enter the EDIT mode. After pressing the button, the first or the last modified parameter of the active program is displayed. Other parameters are selected through the use of the SELECT-keys. The individual value of the momentary displayed parameter can be altered by means of the rotary encoder. For further information, please refer to chapter 7.2, “EDITING”.

5, SELECT-key <

While in EDIT mode, pressing the key selects the corresponding previous parameter. In the Option mode, it is used to select the corresponding previous “Option Page” and in the Store mode, pressing this key switches between program number and name editing.

6, SELECT-key >

While in EDIT mode, the key is used to select the corresponding next parameter. In the Option mode, it serves to select the corresponding next “Option Page” and in the Store mode, pressing this key switches between program number and name editing.

7, OPTION-key

The OPTION-key is used to enter the OPTION menu, allowing the user to alter and check appliance-re- lated settings. For further details, please refer to chapter 9, “OPTION FUNCTIONS”.

2-1

Image 5
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Unpacking and Warranty DSP 244 FeaturesIntroduction IntroductionFront Panel Controls and ConnectionsControls and Connections 14, Level meter indicators Output 1 13, Channel function indicators SUB, LO, MID, HI15, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationLevel Settings Switching the Power onFirst Operation First OperationQuick Start Quick StartLoudspeaker Equalization Over SettingsDelay Alignment Matching the Frequency Response Compressor / Limiter SettingsFull Edit Configurations of the DSPConfigurations of the DSP Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessParameter LINK-TABLE DefaultDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterEdit Mode Selection Setting the LCD ContrastT I O N Option FunctionsEdit Protection VU Level Meter Display ModeCompressor and Limiter Threshold Unit Midi RX / TX Channel settings Temperature Unit settingsCelsius FahrenheitTo Midi Send ParametersTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings Cntct NRS 90247 RS-485 Interface SettingsPGM U01 PGM MutePeci F I C a T IO N S SpecificationsTechnical Specifications IDI General Midi CommandsMidi Midi System Exclusive ImplementationData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty