Dynacord DSP 244 owner manual Way + Fullrange, Way / Mono Sub + Fullrange

Page 15

CONFIGURATIONS OF THE DSP 244

6.3 3 Way + Fullrange

The 3-Way + Fullrange configuration is a 3-way monaural x-over with additional full range output where IN 1 serves as input channel. OUT 1 is the Sub-range channel, OUT 2 the Mid-range channel, OUT 3 the High-range channel, and OUT 4 is the Fullrange channel. OUT 4 can be used for example for monitoring, delayed full range-systems or to provide separate sound reinforcement in adjacent rooms. The internal structure of the 3-Way + Fullrange configuration is shown in the following signal flow diagram. An example of a typical 3-Way + Fullrange configuration is shown in the figure on the right bottom. Two DSP 244s are necessary for stereo operation.

6.4 3 Way / Mono Sub + Fullrange

This configuration also represents a 3-way frequency crossover with additional full range output, with the difference that the Sub-range channel OUT 1 is fed by the summed mono signal of the inputs IN 1 and IN 2. The outputs OUT 2 ... OUT 4 get their signal-feed from the input channel IN 1. OUT 2 is the Mid-range channel, OUT 3 the High-range channel, and OUT 4 the Fullrange channel. OUT 4 can be used for instance for monitoring, delayed full range-systems or to provide separate sound reinforcement in adjacent rooms. The internal structure of the 3-Way / Mono Sub + Fullrange configuration is shown in the following signal flow diagram. An example of a typical system configuration for this structure is shown next to the diagram. Two DSP 244s are necessary for stereo operation.

6-3

Image 15
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionControls and Connections Controls and ConnectionsFront Panel 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Matching the Frequency Response Compressor / Limiter SettingsConfigurations of the DSP Configurations of the DSPFull Edit Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Specifications Technical SpecificationsPeci F I C a T IO N S Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty