Dynacord DSP 244 owner manual Channel EQ1-4

Page 29

P A R A M E T E R S

CHANNEL EQ1-4

The four output channels of the DSP 244 employ a 4-band parametric EQ each which allow to program additional equalization for the individual frequency ranges. This guarantees the optimum frequency response that is matched to the connected loudspeaker components.

 

Parameter

Settings / Value range

Default

 

 

 

 

 

Type

 

 

BYPASS, PEQ, LOSLV, HISLV, HIPASS, LOPASS,

BYPASS

 

 

ALLPASS

 

 

 

 

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

PEQ

 

Q

0.4 - 20.0

0.7

 

 

Gain

-12dB - +12dB

+0dB

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

LOSLV

 

Slope

6dB, 12dB

6 dB

 

 

Gain

-12dB - +12dB

+0dB

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

HISLV

 

Slope

6dB, 12dB

6 dB

 

 

Gain

-12dB - +12dB

+0dB

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

LOPASS

 

Slope

6dB, 12dB

6 dB

 

 

Q

0.4 - 2.0 (for 12dB/octave slope only)

0.7

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

HIPASS

 

Slope

6dB, 12dB

6 dB

 

 

Q

0.4 - 2.0 (for 12dB/octave slope only)

0.7

 

 

 

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

ALLPASS

 

Order

1st, 2nd

1st

 

 

Q

0.4 - 2.0

0.7

 

 

 

 

 

 

 

 

 

 

Type describes the selected filter type. When selecting BYPASS, no effect is applied. PEQ provides a parametric Peak Dip Filter with programmable frequency, quality, and gain. LOSLV / HISLV stand for Low Shelving or High Shelving Equalizer, respectively. Their parameters are: frequency (f), slope, and gain. The parameters of the LOPASS / HIPASS filters are frequency and slope. The ALLPASS filter can be used to compensate phase differences at the x-over frequency.

f (frequency) sets the center-frequency of parametric EQ-types and the cutoff frequency of shelving and Hi-Pass / Lo-Pass filters. With the Allpass filter this is the frequency at which the phase is shifted by 90° (1st order Allpass) or by 180° (2nd order Allpass).

The value of the parameter Q determines the quality or bandwidth of parametric EQs. Higher Q-values result in a narrow banded filter while smaller Q-values result in a wider bandwidth.

The Q-parameter also describes the quality and therefore the graph of the Hi-Pass and Lo-Pass filters.

The Q-parameter is also found in the 2nd order Allpass filter. It is used to set the phase response in the transition band (lower Q-settings result in flat phase response while higher Q-settings produce a steeper phase response; see also examples).

8-7

Image 29
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Unpacking and Warranty DSP 244 FeaturesIntroduction IntroductionFront Panel Controls and ConnectionsControls and Connections 14, Level meter indicators Output 1 13, Channel function indicators SUB, LO, MID, HI15, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationLevel Settings Switching the Power onFirst Operation First OperationQuick Start Quick StartLoudspeaker Equalization Over SettingsDelay Alignment Matching the Frequency Response Compressor / Limiter SettingsFull Edit Configurations of the DSPConfigurations of the DSP Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessParameter LINK-TABLE DefaultDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterEdit Mode Selection Setting the LCD ContrastT I O N Option FunctionsEdit Protection VU Level Meter Display ModeCompressor and Limiter Threshold Unit Midi RX / TX Channel settings Temperature Unit settingsCelsius FahrenheitTo Midi Send ParametersTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings Cntct NRS 90247 RS-485 Interface SettingsPGM U01 PGM MutePeci F I C a T IO N S SpecificationsTechnical Specifications IDI General Midi CommandsMidi Midi System Exclusive ImplementationData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty