Dynacord DSP 244 owner manual Master Delay, Routing

Page 28

P A R A M E T E R S

MASTER DELAY

These delay lines are located in the inputs IN1, IN2 and in the summed input signal IN1+2; all x-over channels are affected.

For instance, this allows to feed different PA-towers at open air concerts with delayed signals.

The delay times are displayed in milliseconds and microseconds while the equivalent distances (unit) are displayed in feet, inches, meters or centimeters. The environmental temperature appears as additional parameter whenever distances are displayed. Thus, up to 3 parameters are available.

 

Parameter

 

 

Settings / Value range

Default

 

 

 

 

 

 

2 ms - 900 ms

 

 

 

1927 µs - 900000 µs

 

Delay

 

2 feet

-

1014 feet

2 ms

 

26 inch

- 12169 inch

 

 

 

 

 

1 m - 309 m

 

 

 

66 cm - 30910 cm

 

 

 

 

 

Unit

 

ms, µs, feet, inch, m, cm

ms

 

 

 

 

Temp

 

-20°C - 60°C

20°C

 

-4°F

-

140°F

 

 

 

 

 

 

 

 

 

The Delay parameter determines the delay time of the corresponding channel or the distance between different loudspeaker clusters.

Unit allows the user to select between time or distance display. Distances are automatically converted into delay times plus the calculation additionally includes the influence of the environmental temperature.

Temp allows you to enter a value for the momentary environmental temperature. This parameter appears only when the selected display-unit is distance. The affect of the environmental temperature on the resulting delay time is automatically included in the calculation.

ROUTING

Any combination of input channels can be assigned to the outputs of the DSP 244. The routing defines which input signal is fed to either one of the output channels (OUT1, OUT2, OUT3, OUT4). Besides routing the signals of the two input channels IN1 and IN2 to one of the outputs, it is also possible to assign the summed, monaural audio signal of both inputs IN1+2 to one of the outputs.

Parameter

Settings / Value range

Default

 

 

 

Source

IN1, IN2, IN1+2

IN1 (OUT 1/2)

IN2 (OUT 3/4)

 

 

 

 

 

 

SUB, LO, MID, HI,

 

Label

LO-MID, LO-MID-HI,

SUB

 

SUB-LO-MID-HI

 

 

 

 

Label allows the setting of the channel-function indicators - SUB, LO, MID, HI - on the front panel of the appliance. These LEDs indicate the individual frequency range which the corresponding channel is actually configured for. The LEDs are meant for indication purposes only - no parameters are changed.

8-6

Image 28
Contents DSP Safety Component has to be Replaced with Original Part only For US and Canada onlyContents DSP 244 Features Unpacking and WarrantyIntroduction IntroductionControls and Connections Controls and ConnectionsFront Panel 13, Channel function indicators SUB, LO, MID, HI 14, Level meter indicators Output 115, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationSwitching the Power on Level SettingsFirst Operation First OperationQuick Start Quick StartDelay Alignment Over SettingsLoudspeaker Equalization Compressor / Limiter Settings Matching the Frequency ResponseConfigurations of the DSP Configurations of the DSPFull Edit N Figurations of the DSP Stereo 2 Way3 Way + Fullrange 3 Way / Mono Sub + Fullrange3 Way / Independent Sub + Fullrange 4 Way2-IN-4 E R a T I O N OperationEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs R a M E T E R S ParametersParameter Access Parameter ACCESS-TABLEDefault Parameter LINK-TABLEDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Master Delay RoutingChannel EQ1-4 R a M E T E R S Hipass X-OVER Lopass X-OVERR a M E T E R S Channel Delay Compressor Limiter LevelSetting the LCD Contrast Edit Mode SelectionT I O N Option FunctionsCompressor and Limiter Threshold Unit VU Level Meter Display ModeEdit Protection Temperature Unit settings Midi RX / TX Channel settingsCelsius FahrenheitSend Parameters To MidiTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings NRS 90247 RS-485 Interface Settings CntctPGM U01 PGM MuteTechnical Specifications SpecificationsPeci F I C a T IO N S General Midi Commands IDIMidi Midi System Exclusive ImplementationData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Warranty Garantie