Dynacord DSP 244 owner manual = 1kHz, Gain = -12dB

Page 27

P A R A M E T E R S

PEQ:

f = 1kHz, Gain = -12dB

Q = 0.5, 1.0, 5.0, 20.0

Low Shelving Filter (LOSLV):

f = 200Hz, Slope = 6dB

High Shelving Filter (HISLV):

f = 2000Hz, Slope = 6dB

Gain = +3dB, +6dB, +9dB, +12dB Gain = +3dB, +6dB, +9dB, +12dB

Low Shelving Filter (LOSLV):

f = 200Hz, Slope = 12dB,

Gain = +3dB, +6dB, +9dB, +12dB

High Shelving Filter (HISLV):

f = 2000Hz, Slope = 12dB,

Gain = +3dB, +6dB, +9dB, +12dB

Hi-Pass Filter (HIPASS):

f = 100Hz, Slope = 6dB, 12dB

Q = 0.7, 1.0, 2.0

Lo-Pass Filter (LOPASS):

f = 5000Hz, Slope = 6dB, 12dB

Q = 0.7, 1.0, 2.

8-5

Image 27
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionControls and Connections Controls and ConnectionsFront Panel 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Matching the Frequency Response Compressor / Limiter SettingsConfigurations of the DSP Configurations of the DSPFull Edit Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Specifications Technical SpecificationsPeci F I C a T IO N S Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty