Dynacord DSP 244 owner manual Hipass X-OVER, Lopass X-OVER

Page 31

P A R A M E T E R S

HIPASS X-OVER

The frequency crossover filter consists of a low pass filter in one channel and a high pass filter in the adjacent channel. Here, the frequency x-over filter’s Hi-Pass parameters are set. The parameters of the corresponding Lo-Pass should be set to the same values. An x-over filter provides the parameters “Type” and “f”.

Parameter

Settings / Value range

Default

 

 

 

 

thru, 6 dB,

 

 

12dB Q0.5, 12dB Q0.6, 12dB Q0.7, 12dB Q0.8,

 

Type

12dB Q1.0, 12dB Q1.2, 12dB Q1.5, 12dB Q2.0

thru

Bessel 12 dB, Butter 12 dB, Linkwitz 12 dB,

 

 

 

Bessel 18 dB, Butter 18 dB,

 

 

Bessel 24 dB, Butter 24 dB, Linkwitz 24 dB

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

 

 

 

Pol

norm, inv

norm

 

 

 

The Type parameter defines the filter characteristics of the x-over Hi-Pass filter. Different slopes and filter responses (6dB, 12dB with different Q values, Bessel, Butterworth, Linkwitz-Riley) are available and the filter can be bypassed. The corresponding Lo-Pass filter should be set to the same characteristics.

The f parameter (frequency) sets the x-over Hi-Pass filter’s cutoff frequency. The corresponding Lo-Pass filter should be set to the same cutoff frequency.

Pol defines the polarity of the corresponding channel. Depending on the characteristic of the frequency crossover filter, inverting the polarity of a channel’s signal may become necessary; i. e.: set a negative polarity. Some filter types generate phase responses that lead to significant level reduction in the overall audio signal at the crossover frequency. This negative effect can be eliminated by inverting the polarity of the output that carries the low-frequency signal.

The following table provides you with a list of all filter types for which a channel’s signal has to be inverted for the corresponding filter pair.

Bessel 12 dB

Butterworth 12 dB

Bessel 18 dB

Bessel 24 dB

In the Standard Edit Mode, depending on the selected type of filter, channel inversion is automatically set.

LOPASS X-OVER

The frequency crossover filter consists of a low pass filter in one channel and a high pass filter in the adjacent channel. Here, the frequency x-over filter’s Lo-Pass parameters are set. The parameters of the corresponding Hi-Pass should be set to the same values. An x-over filter provides the parameters “Type” and “f”.

Parameter

Settings / Value range

Default

 

 

 

 

thru, 6 dB,

 

 

12dB Q0.5, 12dB Q0.6, 12dB Q0.7, 12dB Q0.8,

 

Type

12dB Q1.0, 12dB Q1.2, 12dB Q1.5, 12dB Q2.0

thru

Bessel 12 dB, Butter 12 dB, Linkwitz 12 dB,

 

 

 

Bessel 18 dB, Butter 18 dB,

 

 

Bessel 24 dB, Butter 24 dB, Linkwitz 24 dB

 

 

 

 

f

20Hz - 20kHz

1.00 kHz

 

 

 

Pol

norm, inv

norm

 

 

 

The Type parameter defines the filter characteristics of the x-over Lo-Pass filter. Different slopes and filter responses (6dB, 12dB with different Q values, Bessel, Butterworth, Linkwitz-Riley) are available and the filter can be bypassed. The corresponding Hi-Pass filter should be set to the same characteristics.

8-9

Image 31
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionControls and Connections Controls and ConnectionsFront Panel 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartDelay Alignment Over SettingsLoudspeaker Equalization Matching the Frequency Response Compressor / Limiter SettingsConfigurations of the DSP Configurations of the DSPFull Edit Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NCompressor and Limiter Threshold Unit VU Level Meter Display ModeEdit Protection Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Technical Specifications SpecificationsPeci F I C a T IO N S Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty