9. OPTION FUNCTIONS

The “option programs” offer several additional, important information and preference settings for the DSP 244.

Using the SELECT keys you can choose between the following functions:

-LCD CONTRAST setting

-EDIT MODE selection

-COMPR & LIMIT THRESH UNIT - setting of the compressor’s and limiter’s threshold unit

-VU MODE - level meter display mode setting

-LOCK CODE - edit protection

-TEMPERATURE UNIT settings

-MIDI RX / TX CHANNEL settings

-SEND EDITED PARAMS - parameter transmission

-RS232 TO MIDI transmission

-CONTACT INTERFACE - NRS 90246 Contact Closure Interface settings

-NRS 90247 RS-485 Interface Settings

-SOFTWARE REV - display of the internal software revision number

Press OPTION (7) to activate the option programs.

The last used option program appears on the display; e. g.:

Use the two SELECT keys (5 and 6) to select the desired option page and set the corresponding values using the rotary encoder (10).

You can leave the OPTION mode by pressing OPTION (7) again, or you can press any other MODE key (i. e. pressing the EDIT key switches to Edit mode).

9.1 SETTING THE LCD CONTRAST

The LCD contrast or viewing angle can be set in a range of -10 (bottom view) and +10 (top view).

9.2 EDIT MODE SELECTION

This page allows you to choose the operation mode which the DSP 244 is operated in. The display shows the following selection menu:

When you select No edit, editing and program selection is not possible.

In Full edit mode, all parameter settings are accessible.

9-1

Image 36
Contents DSP Safety Component has to be Replaced with Original Part only For US and Canada onlyContents DSP 244 Features Unpacking and WarrantyIntroduction IntroductionControls and Connections Controls and ConnectionsFront Panel 13, Channel function indicators SUB, LO, MID, HI 14, Level meter indicators Output 115, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationSwitching the Power on Level SettingsFirst Operation First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Compressor / Limiter Settings Matching the Frequency ResponseConfigurations of the DSP Configurations of the DSPFull Edit N Figurations of the DSP Stereo 2 Way3 Way + Fullrange 3 Way / Mono Sub + Fullrange3 Way / Independent Sub + Fullrange 4 Way2-IN-4 E R a T I O N OperationEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs R a M E T E R S ParametersParameter Access Parameter ACCESS-TABLEDefault Parameter LINK-TABLEDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Master Delay RoutingChannel EQ1-4 R a M E T E R S Hipass X-OVER Lopass X-OVERR a M E T E R S Channel Delay Compressor Limiter LevelSetting the LCD Contrast Edit Mode SelectionT I O N Option FunctionsVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Temperature Unit settings Midi RX / TX Channel settingsCelsius FahrenheitSend Parameters To MidiTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings NRS 90247 RS-485 Interface Settings CntctPGM U01 PGM MuteSpecifications Technical SpecificationsPeci F I C a T IO N S General Midi Commands IDIMidi Midi System Exclusive ImplementationData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Warranty Garantie