CONTROLS AND CONNECTIONS

8, STORE-key

This key allows the user to store edited programs in one of the user-definable program presets (U01 - U30) or to copy programs from one preset to another. For further information, please refer to chapter 7.4,

“STORE PROGRAMS AND PROGRAM NAMES”.

9, RECALL-key

Pressing this key lets you enter the PROGRAM SELECTION mode where you can select factory or user-definable program presets through using the rotary encoder. By pressing the RECALL-key, the selected program is acknowledged and gets loaded.

For further information, please refer to chapter 7.1, ”PROGRAM SELECTION”.

10, Rotary encoder with push-button function

While in PROGRAM SELECTION mode, rotating the encoder selects the desired program. It is activated by pressing the RECALL-key. In EDIT mode, the encoder lets you alter parameter setting or leaf through function blocks. Simultaneously dialing the encoder while keeping it pressed increases the speed in which the parameter values are changed. For further details, please refer to the chapter “OPERATION” starting on page 7-1.

11, OUTPUT-controls 1 - 4

These rotary controls are used to set the output levels of channels 1 to 4, allowing to match the DSP 244 to the input levels of the devices chained in sequence. Correctly setting these controls results in an improved S/N ratio. In most cases, good results are achieved when setting the controls to their center position (-6). The digital output gain control should be used when higher output levels are needed. Use the rotary controls OUTPUT 1 - 4 to attenuate the output levels. It is not recommended to use the digital output gain control for massive attenuation, since this would decline the dynamic range of the D/A-con- verters.

The rotary controls also provide push-button-functionality, which, in the EDIT mode is used to switch between function blocks, channel-related; i. e.: pressing a rotary control switches to the corresponding output channel. For further details, please refer to chapter 7.2, “EDITING”.

12, MUTE-keys 1 - 4

These keys allow to mute the output signal of the corresponding output channels. Pressing a key once switches the mute-function ON; the key’s red LED lights. Pressing the button again switches the mute-function OFF; the key’s LED is dimmed again.

13, Channel function indicators SUB, LO, MID, HI

These LEDs indicate, which frequency band the corresponding channel is set to. If a channel is configured for full range operation, all its function-LEDs are simultaneously lit.

14, Level meter indicators OUTPUT 1 - 4

These LEDs indicate the peak level of the corresponding outputs. The DSP 244 should be operated in a range, so that the clip-LEDs are not lit. Otherwise, this could lead to internal clipping. The indicators can be set to “Peak-Hold” or “Slow-Mode”.

15, Compressor indicators OUTPUT 1 - 4

The COMP-LEDs light, when the compressor / limiter of the corresponding channel is activated; e. g.: when the audio signal level exceeded the previously set threshold and therefore the output level is compressed or limited.

16, POWER ON/OFF-switch

This switch turns the DSP 244’s mains power on or off.

2-2

Image 6
Contents DSP Safety Component has to be Replaced with Original Part only For US and Canada onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionControls and Connections Controls and ConnectionsFront Panel 15, Compressor indicators Output 1 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 16, Power ON/OFF-switchRear Panel Balanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Unbalanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Compressor / Limiter Settings Matching the Frequency ResponseConfigurations of the DSP Configurations of the DSPFull Edit N Figurations of the DSP Stereo 2 Way3 Way + Fullrange 3 Way / Mono Sub + Fullrange3 Way / Independent Sub + Fullrange 4 Way2-IN-4 E R a T I O N OperationEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs R a M E T E R S ParametersParameter Access Parameter ACCESS-TABLEDescription of Parameters DefaultParameter LINK-TABLE Master EQ1-5PEQ = 1kHz, Gain = -12dB Master Delay RoutingChannel EQ1-4 R a M E T E R S Hipass X-OVER Lopass X-OVERR a M E T E R S Channel Delay Compressor Limiter LevelT I O N Setting the LCD ContrastEdit Mode Selection Option FunctionsVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Celsius Temperature Unit settingsMidi RX / TX Channel settings FahrenheitTo RS232 Send ParametersTo Midi RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings PGM U01 NRS 90247 RS-485 Interface SettingsCntct PGM MuteSpecifications Technical SpecificationsPeci F I C a T IO N S Midi General Midi CommandsIDI Midi System Exclusive ImplementationData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Warranty Garantie