P A R A M E T E R S

LIMITER

The limiter provides additional protection against the occurrence of clipping and overload conditions. The maximum level of the audio signal is limited to the set threshold value. The short attack times guarantee that even sudden peak levels are effectively attenuated.

 

Parameter

 

Settings / Value range

Default

 

 

 

 

 

Thrsh

 

0.27V - 8.70V

 

8.70V

 

 

 

 

 

Release

 

50ms - 999ms

 

100ms

 

 

 

 

 

The Thrsh parameter (Threshold) defines the level at which the limiter starts operating. Signal levels below this value are not influenced. As soon as levels reach or exceed the threshold value, they are automatically limited to this value. Normally, the limiter threshold should be set to a value that is some dBs above the compressor threshold. This provides the best protection against loudspeaker damage as a result from sudden peak levels.

Release defines the limiter’s release time, after the signal level has dropped again below the threshold value. When the signal’s level drops below the threshold, the audio signal’s gain is processed to return to its original value. This signal processing follows an exponential curve, so that the volume change is appropriate for the human hearing. When selecting a release value that is too short, the signal level rises too fast, which also results in pumping. On the other hand, too long release times often lead to a dramatic loss in dynamic.

LEVEL

Each output channel employs a digital level control and a polarity switch. These controls provide the possibility to compensate volume differences and phase shift between the different x-over channels.

Parameter

Settings / Value range

Default

 

 

 

Level

Off, -30.0 dB - +6.0 dB

0.0 dB

 

 

 

Polarity

normal, inverted

normal

 

 

 

The Level parameter sets the output level of the corresponding output channel. The setting can be performed in steps of 0.5dB.

Polarity defines the polarity of the audio signals of the outputs 1 - 4 . This parameter is also accessible in the HIPASS X-OVER or LOPASS X-OVER display windows. The corresponding descriptions provide you with additional information about the correct setting of a channel’s polarity.

8-13

Image 35
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionFront Panel Controls and ConnectionsControls and Connections 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartLoudspeaker Equalization Over SettingsDelay Alignment Matching the Frequency Response Compressor / Limiter SettingsFull Edit Configurations of the DSPConfigurations of the DSP Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NEdit Protection VU Level Meter Display ModeCompressor and Limiter Threshold Unit Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Peci F I C a T IO N S SpecificationsTechnical Specifications Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty