Dynacord DSP 244 owner manual Command Parser Code Table

Page 45

 

 

 

 

 

Command Parser Code Table

 

 

 

 

 

 

 

 

 

 

 

 

UNIT-ID

 

 

 

Tree

 

Value

Unit

 

 

 

 

 

 

 

 

 

 

 

 

/ID1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELAY

 

 

 

1.927... 900.0

ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FREQ

 

 

20 ... 20000

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAIN

 

 

-12 ...12

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QUAL

 

 

0.4 ... 20.0

 

 

 

 

 

 

 

SLOPE

 

 

6,12

dB/Octave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

 

 

BYPASS,PEQ,LOSLV,

 

 

 

 

 

 

 

 

 

HISLV,HIPASS,LOPASS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ2/

... EQ5/

 

see EQ1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN2/

 

 

 

see IN1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSUM/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELAY

 

 

 

1.927 ... 900.0

ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT1/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ1/

 

 

 

 

 

 

 

 

 

 

 

FREQ

 

 

20 ... 20000

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAIN

 

 

-12 ... 12

dB

 

 

 

 

 

 

QUAL

 

 

0.4 ... 20.0

 

 

 

 

 

 

 

SLOPE

 

 

6,12 *)

dB/Octave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

 

 

BYPASS,PEQ,LOSLV,

 

 

 

 

 

 

 

 

 

HISLV,HIPASS,LOPASS, ALLPASS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ2/

... EQ4/

 

see EQ1/

 

 

 

 

 

 

 

 

 

 

 

 

 

XOVER/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIPASS/

 

 

 

 

 

 

 

 

 

 

 

FREQ/

 

20 ... 20000

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THRU,6DB,12DBQ0.5,

 

 

 

 

 

 

 

 

 

 

12DBQ0.6,12DBQ0.7,

 

 

 

 

 

 

 

 

 

 

12DBQ0.8,12DBQ1.0,

 

 

 

 

 

 

 

 

 

 

12DBQ1.2,12DBQ1.5,

 

 

 

 

 

 

 

 

TYPE/

 

12DBQ2.0,

 

 

 

 

 

 

 

 

 

 

LINKW12DB,BESSEL12DB

 

 

 

 

 

 

 

 

 

 

BUTTER12DB,BESSEL18DB

 

 

 

 

 

 

 

 

 

 

BUTTER18DB,LINKW24DB,

 

 

 

 

 

 

 

 

 

 

BESSEL24DB,BUTTER24DB

 

 

 

 

 

 

 

LOPASS/

 

see HIPASS/

 

 

 

 

 

DELAY

 

 

 

0 ... 900.0

ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POLARITY

 

 

 

NORMAL,INVERTED

 

 

 

 

 

LEVEL

 

 

 

OFF, -30 ... 6 dB

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEVREL

 

 

 

-36 ... +36

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROUTING

 

 

 

IN1,IN2,IN1+2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

 

 

 

1,0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATIO

 

 

1OVER1.0,1OVER1.4,

 

 

 

 

 

 

 

 

 

1OVER2.0,1OVER4.0, 1OVER8.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THRESH

 

 

-30 ... 0

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTACK

 

 

0 ... 99

ms

 

 

 

 

 

 

RELEASE

 

 

50 ... 999

ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMITER/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THRESH

 

 

-30 ... 0

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELEASE

 

 

50 ... 999

ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEDS/

 

 

 

 

 

 

 

 

 

 

 

SUB

 

 

ON, OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO

 

 

ON, OFF

 

 

 

 

 

 

 

MID

 

 

ON, OFF

 

 

 

 

 

 

 

HI

 

 

ON, OFF

 

 

 

OUT2/ ... OUT4/

 

 

 

see OUT1/

 

 

 

 

 

MISC/

 

 

 

 

 

 

 

 

 

 

 

DELAY_IN_UNIT

 

 

 

US,MS,FEET,INCH,M,CM

 

 

 

 

 

DELAY_OUT_UNIT

 

 

 

US,MS,FEET,INCH,M,CM

 

 

 

 

 

TEMPERATURE

 

 

 

-4 ... 140

°F

 

 

 

 

TEMPERATURE_UNIT

 

 

 

CELSIUS,FAHRENHEIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROGNAME

 

 

 

Up to 16 Characters

 

 

 

 

 

 

 

 

(ASCII Code <= 7Fh)

 

 

 

 

 

 

 

 

 

 

 

/ID2/

... /ID32/

 

 

 

 

see /ID1/

 

 

*)

For Type = Allpass:

Slope = 6: First Order Allpass

 

 

 

 

 

Slope = 12: Second Order Allpass

 

 

Example:

/ID3/ OUT1/ XOVER/ HIPASS/ FREQ 1500

10-4

Image 45
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Unpacking and Warranty DSP 244 FeaturesIntroduction IntroductionControls and Connections Controls and ConnectionsFront Panel 14, Level meter indicators Output 1 13, Channel function indicators SUB, LO, MID, HI15, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationLevel Settings Switching the Power onFirst Operation First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Matching the Frequency Response Compressor / Limiter SettingsConfigurations of the DSP Configurations of the DSPFull Edit Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessParameter LINK-TABLE DefaultDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterEdit Mode Selection Setting the LCD ContrastT I O N Option FunctionsVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Midi RX / TX Channel settings Temperature Unit settingsCelsius FahrenheitTo Midi Send ParametersTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings Cntct NRS 90247 RS-485 Interface SettingsPGM U01 PGM MuteSpecifications Technical SpecificationsPeci F I C a T IO N S IDI General Midi CommandsMidi Midi System Exclusive ImplementationData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty