Dynacord DSP 244 owner manual Installation manuals for interface cards

Page 47

RETROFITTING INSTRUCTIONS

10.3.2 Installation manuals for interface cards:

Contact Closure Interface

(NRS 90246, EDP-No. 112766)

RS-485 Interface

(NRS 90247, EDP-No. 112767)

Contents NRS 90246:

1 x Information sheet NRS 90246

1 x Printed board assembly Contact Closure (83114)

1 x Rear plate blinding

4 x Screws M3 x 6

Contents NRS 90247:

1 x Information sheet NRS 90247

1 x Information sheet “Important Information”

1x Printed board assembly RS-485 (83115)

1x Rear plate blinding

4x Screws M3 x 6

Installation instructions NRS 90246, NRS 90247:

1.Switch the DSP 244’s power off and unplug the mains cord.

2.Remove the cover plate after unscrewing 2 screws on the top, 4 on the sides, and 3 on the rear.

3.Loosen the blinding on the rear plate (2 screws on the rear).

4.Install the extension kit’s printed board assembly at the correct destination (see figure below).

5.First, tighten the screws at the rear plate (A) and then the two screws that fix the printed board assembly in place at the bottom plate (B).

6.Using the 26-pole flat wire cable (C), establish the connections between the printed board assembly of the extension kit and the Analog Board (printed board assembly 80448).

7.Re-attach the cover plate and tighten its screws. Re-insert the mains cord and switch the appliance’s power on. The newly installed interface is automatically recognized.

8.Now, you are able to make all necessary software settings for the interface in the OPTION mode (see also chapter 9, OPTION FUNCTIONS).

Position of the NRS 90246, NRS 90247 in the DSP 244

10-6

Image 47
Contents DSP For US and Canada only Safety Component has to be Replaced with Original Part onlyContents Introduction DSP 244 FeaturesUnpacking and Warranty IntroductionFront Panel Controls and ConnectionsControls and Connections 16, Power ON/OFF-switch 13, Channel function indicators SUB, LO, MID, HI14, Level meter indicators Output 1 15, Compressor indicators Output 1Rear Panel Unbalanced INPUT/OUTPUT configuration Installation and ConnectionsInstallation and Connections Balanced INPUT/OUTPUT configurationFirst Operation Switching the Power onLevel Settings First OperationQuick Start Quick StartLoudspeaker Equalization Over SettingsDelay Alignment Matching the Frequency Response Compressor / Limiter SettingsFull Edit Configurations of the DSPConfigurations of the DSP Stereo 2 Way N Figurations of the DSP3 Way / Mono Sub + Fullrange 3 Way + Fullrange4 Way 3 Way / Independent Sub + Fullrange2-IN-4 Operation E R a T I O NEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs Parameters R a M E T E R SParameter ACCESS-TABLE Parameter AccessMaster EQ1-5 DefaultParameter LINK-TABLE Description of ParametersPEQ = 1kHz, Gain = -12dB Routing Master DelayChannel EQ1-4 R a M E T E R S Lopass X-OVER Hipass X-OVERR a M E T E R S Channel Delay Compressor Level LimiterOption Functions Setting the LCD ContrastEdit Mode Selection T I O NEdit Protection VU Level Meter Display ModeCompressor and Limiter Threshold Unit Fahrenheit Temperature Unit settingsMidi RX / TX Channel settings CelsiusRS-232 to Midi data transmission Send ParametersTo Midi To RS232NRS 90246 Contact Closure Interface settings PGM Mute NRS 90247 RS-485 Interface SettingsCntct PGM U01Peci F I C a T IO N S SpecificationsTechnical Specifications Midi System Exclusive Implementation General Midi CommandsIDI MidiData Command Parser Code Table Retrofitting Instructions Installation instructions NRSRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Garantie Warranty