Dynacord DSP 244 owner manual Parameter Access, Parameter ACCESS-TABLE

Page 24

P A R A M E T E R S

8.1 PARAMETER ACCESS

Depending on the actual configuration, only certain parameters are relevant. To provide a better overview and prevent erroneous operation, in the STANDARD Edit mode only those parameters are accessible. Additionally and to further improve operational comfort, corresponding parameters are linked. For Instance, in the Stereo 2-Way configuration, the Master EQs, the Master delays, the outputs OUT1 / OUT3 and OUT2 / OUT4, and the X-Over parameters are linked for mutual setting.

For information about the parameters that are accessible with a certain configuration and parameters that are linked, please refer to the following tables.

8.1.1 PARAMETER ACCESS-TABLE

 

 

 

 

STANDARD Mode 1)

 

 

FULL

 

 

 

 

 

 

EDIT

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

Stereo

 

 

3 Way

3 Way

 

 

 

 

 

2 Way /

3 Way

 

Independ.

 

 

 

 

Stereo

 

Mono

 

 

Full

 

Mono

+

 

Sub

4 Way

2-In-4

 

2 Way

 

Sub +

Edit

 

Sub +

Fullrange

 

+

 

 

 

 

 

Fullrange

 

 

 

 

 

Fullrange

 

 

Fullrange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROUTING

N O

N O

N O

 

N O

N O

N O

N O

YES

 

 

 

 

 

 

 

 

 

 

IN2 EQs

Y E S

YES

N O

 

Y E S

YES

N O

Y E S

YES

 

 

 

 

 

 

 

 

 

 

IN2 Delay

Y E S

YES

N O

 

Y E S

YES

N O

Y E S

YES

 

 

 

 

 

 

 

 

 

 

IN1+2 Delay

N O

YES

N O

 

Y E S

N O

N O

N O

YES

 

 

 

 

 

 

 

 

 

 

Label

N O

N O

N O

 

N O

N O

N O

N O

YES

 

 

 

 

 

 

 

 

 

 

OUT1 HIPASS

N O

N O

N O

 

N O

N O

N O

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT1 LOPASS

Y E S

YES

Y E S

 

Y E S

YES

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT2 HIPASS

Y E S

YES

Y E S

 

Y E S

YES

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT2 LOPASS

N O

N O

Y E S

 

Y E S

YES

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT3 HIPASS

N O

YES

Y E S

 

Y E S

YES

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT3 LOPASS

Y E S

N O

N O

 

N O

N O

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT4 HIPASS

Y E S

YES

Y E S

 

Y E S

YES

Y E S

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT4 LOPASS

N O

N O

N O

 

N O

N O

N O

Y E S

YES

XOVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES: Parameter is available

NO: Parameter is not available

1) STANDARD Mode can be selected in the DSP 244 Editor software

8-2

Image 24
Contents DSP Safety Component has to be Replaced with Original Part only For US and Canada onlyContents DSP 244 Features Unpacking and WarrantyIntroduction IntroductionControls and Connections Controls and ConnectionsFront Panel 13, Channel function indicators SUB, LO, MID, HI 14, Level meter indicators Output 115, Compressor indicators Output 1 16, Power ON/OFF-switchRear Panel Installation and Connections Installation and ConnectionsBalanced INPUT/OUTPUT configuration Unbalanced INPUT/OUTPUT configurationSwitching the Power on Level SettingsFirst Operation First OperationQuick Start Quick StartOver Settings Delay AlignmentLoudspeaker Equalization Compressor / Limiter Settings Matching the Frequency ResponseConfigurations of the DSP Configurations of the DSPFull Edit N Figurations of the DSP Stereo 2 Way3 Way + Fullrange 3 Way / Mono Sub + Fullrange3 Way / Independent Sub + Fullrange 4 Way2-IN-4 E R a T I O N OperationEditing E R a T I O N Store Programs and Program Names Modifying Factory Preset Programs R a M E T E R S ParametersParameter Access Parameter ACCESS-TABLEDefault Parameter LINK-TABLEDescription of Parameters Master EQ1-5PEQ = 1kHz, Gain = -12dB Master Delay RoutingChannel EQ1-4 R a M E T E R S Hipass X-OVER Lopass X-OVERR a M E T E R S Channel Delay Compressor Limiter LevelSetting the LCD Contrast Edit Mode SelectionT I O N Option FunctionsVU Level Meter Display Mode Compressor and Limiter Threshold UnitEdit Protection Temperature Unit settings Midi RX / TX Channel settingsCelsius FahrenheitSend Parameters To MidiTo RS232 RS-232 to Midi data transmissionNRS 90246 Contact Closure Interface settings NRS 90247 RS-485 Interface Settings CntctPGM U01 PGM MuteSpecifications Technical SpecificationsPeci F I C a T IO N S General Midi Commands IDIMidi Midi System Exclusive ImplementationData Command Parser Code Table Installation instructions NRS Retrofitting InstructionsRetrofitting Instructions Installation manuals for interface cards Blockdiagramm / Block Diagram Flussdiagramm / Flow Diagram Abmessungen / Dimensions Warranty Garantie