GTO 12, R4854 01, 10 Technical Specifications, Drive, Power, Control, Operational Capacity

Page 11

Technical Specifications

GTO/ACCESS SYSTEMS 4000XLS AUTOMATIC GATE OPERATOR

DRIVE

Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316

(Not solar compatible) is recommended in extreme cold temperatures.

Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 375 rpm.

Maximum opening arc of 110º. Approximate opening time (90º): 16-20 seconds, depending on weight of gate.

POWER

The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.

Battery charge is maintained by a 120 Vac, 18 Vac output transformer. Blade-style control board fuse is rated for 25 A.

NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board.

For optional solar charging see page 2.

CONTROL

GTO microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog).

A circuit on the control board regulates charging. “Sleep draw” is 25 mA; “active draw” is 5 to 9 A.

Auto-memorization of digital transmitter code.

GTO remote-mounted RF receiver tuned to 318 MHz.

Operator length with push-pull tube fully retracted is 46 1/4”, mounting point to mounting point, arm stroke 22” max.

Minimum gate length is 6 ft.

Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.

Power terminal block accommodates a transformer or solar panels (not both).

DIP switches simplify setup of gate operator.

Accessory terminal block fully compatible with GTO push button controls, digital keypads, loops detectors, etc.

Control board allows connection of safety edge sensors and photoelectric sensors.

Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.

OPERATIONAL CAPACITY

The Gate Capacity Chart shows approximate cycles, per day, you can expect from the 4000XLS Automatic Gate

Operators when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.

GTO/ACCESS SYSTEMS 4000XLS Gate Capacity Chart

Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery

Gate Length

20 ft.

135

130

125

120

115

110

105

100

16 ft.

140

135

130

125

120

115

110

105

12 ft.

145

140

135

130

125

120

115

110

6 – 10 ft.

150

145

140

135

130

125

120

115

 

300 lb.

400 lb.

500 lb.

600 lb.

700 lb.

800 lb.

900 lb.

1000 lb.

Gate Weight

NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.

To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed on page 2.

* An operation cycle is one full opening and closing of the gate.

These specifications are subject to change without notice.

GTO 4000XLS Instruction Manual © 01.10.12 1

Image 11
Contents 4000XLS For Your Records When You Know Multiply By To FindClass Rating Table of Contents Please Read This First 24/7 Troubleshooting Wizard http//support.gtoinc.comBefore YOU Begin to Install Your Automatic Gate Operator How To Manually Open and Close the Gate Important Safety InstructionsFor The Consumer Important Safety InstructionsAny control device Within gray area Never InstallInstall Warning Signs Entrapment Protection Required Safety Precautions for GatesSecondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ADC Swing Series Control Technical SpecificationsPower DriveZone Watts Determine Charging Option for Battery Transformer or SolarSolar Panel and Gate Activity Chart Before You BeginPrepare the Gate Check Direction of Gate SwingBracket BOX HB4000 4000XLS Parts ListTools Needed Materials You may Need for the InstallationPull-To-Open Gates Gate Opens into the Property Install the OperatorInstallation Overview Install the Post Bracket AssemblyStep Hair pin clip Check ClearanceAttach Operator Install Gate BracketInstall Closed Position Stop Plate Receiver cable Mount the Control Box and ReceiverMount the receiver Never Splice Wires Connect Operator Power CableConnect the Power Input Make sure the exposed wires do not touch each other Connect BatteryBe certain not to let the exposed wires touch each other To Close Control Board SettingsSet Closed Position Limit for Pull-To-Open Applications Set Auto Close Time Adjust the Stall Force Setting24/7 Troubleshooting Wizard http Support.gtoinc.com Program Your Personal Transmitter SettingDIP Switches DIP Switch SettingsInput Connections Connecting AccessoriesWiring Accessories Swinging gates shall not open into public access areas Push-To-Open Installation InformationInstall the Operator Set Control Board for Push-To-Open Setting the Open Position Limit Push-To-Open InstallationsColumn Installation Generation 3 Audible Feedback Troubleshooting GuideSymptom Diagnosis Check Voltage Readings Generation 3 Visual Feedback800am-700pm Monday-Friday EST Repair ServiceAccessories for 4000XLS Gooseneck Pedestal F100/F110 Residential Wireless Entry Intercom F3100MBCWireless Vehicle Sensor R4500 Wireless Driveway Alarm R4450Push Button Control RB101 Replacement Transformer RB570Photo Beams R4222 Pin Lock FM345Access Systems