Connect the Power Input

IMPORTANT:

The transformer is designed and intended for indoor use. If the transformer can only be plugged into an outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.

The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire [RB509]. This gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.

DO NOT use telephone wire or solid wire.

NEVER SPLICE WIRES. Splicing permits corrosion and seriously degrades the wire’s ability to carry an adequate current.

NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will damage the control board.

If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10 watts solar charging power [FM122/FM123] to charge the battery. Refer to the Solar Panels and Gate Activity Chart on page 2.

ON/OFF Switch

Step 1

Make sure the control box power switch is OFF.

Step 2

Select the electrical outlet outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid (allow for an additional 6” to be pulled into the control box).

Step 3

Lay the low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Bury the wire in the trench.

Step 4

Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6” to 8” of wire into the control box.

FUSE

25

BATT+

BATT-

SLAVE INPUTS

MASTER INPUTS

RECEIVER

Low Voltage Wire

Power Cable from

from Transformer

Master Arm

or Solar Panel

 

PVC Pipe

 

GTO 4000XLS Instruction Manual © 01.10.12 13

Image 23
Contents 4000XLS For Your Records When You Know Multiply By To FindClass Rating Table of Contents Please Read This First 24/7 Troubleshooting Wizard http//support.gtoinc.comBefore YOU Begin to Install Your Automatic Gate Operator How To Manually Open and Close the Gate Important Safety InstructionsFor The Consumer Important Safety InstructionsAny control device Within gray area Never InstallInstall Warning Signs Entrapment Protection Required Safety Precautions for GatesSecondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ADC Swing Series Control Technical SpecificationsPower DriveZone Watts Determine Charging Option for Battery Transformer or SolarSolar Panel and Gate Activity Chart Before You BeginPrepare the Gate Check Direction of Gate SwingBracket BOX HB4000 4000XLS Parts ListTools Needed Materials You may Need for the InstallationPull-To-Open Gates Gate Opens into the Property Install the OperatorInstallation Overview Install the Post Bracket AssemblyStep Hair pin clip Check ClearanceAttach Operator Install Gate BracketInstall Closed Position Stop Plate Receiver cable Mount the Control Box and ReceiverMount the receiver Never Splice Wires Connect Operator Power CableConnect the Power Input Make sure the exposed wires do not touch each other Connect BatteryBe certain not to let the exposed wires touch each other To Close Control Board SettingsSet Closed Position Limit for Pull-To-Open Applications Set Auto Close Time Adjust the Stall Force Setting24/7 Troubleshooting Wizard http Support.gtoinc.com Program Your Personal Transmitter SettingDIP Switches DIP Switch SettingsInput Connections Connecting AccessoriesWiring Accessories Swinging gates shall not open into public access areas Push-To-Open Installation InformationInstall the Operator Set Control Board for Push-To-Open Setting the Open Position Limit Push-To-Open InstallationsColumn Installation Generation 3 Audible Feedback Troubleshooting GuideSymptom Diagnosis Check Voltage Readings Generation 3 Visual Feedback800am-700pm Monday-Friday EST Repair ServiceAccessories for 4000XLS Gooseneck Pedestal F100/F110 Residential Wireless Entry Intercom F3100MBCWireless Vehicle Sensor R4500 Wireless Driveway Alarm R4450Push Button Control RB101 Replacement Transformer RB570Photo Beams R4222 Pin Lock FM345Access Systems