GTO 12, R4854 01, 10 installation manual Generation 3 Visual Feedback, Voltage Readings

Page 35

Generation 3 Visual Feedback

SYMPTOM

DIAGNOSIS

CHECK:

Status (clear)1 blink

Cycle Terminal

• Disconnect the push button, keypad, intercom keypad, or

 

Shorted

any other accessory wired to this terminal.

 

 

• Try the remote. If the remote works, then the problem is

 

 

the accessory.

Status (clear) 2

Safety Terminal

• Disconnect the loop detector, photo beam, or any other

blinks

Shorted

accessory wired to this terminal.

 

 

• Try the remote. If the remote works, the problem is the

 

 

accessory.

Status (clear) 3

Exit Terminal

• Disconnect exit wand, loop detector, photo beam, or any

blinks

Shorted

other accessory wired to this terminal.

 

 

• Try remote. If the remote works, the problem is the

 

 

accessory.

Status (clear) 4

Shadow Terminal

• Disconnect the loop detector, photo beam, or any other

blinks

Shorted

accessory wired to this terminal.

 

 

• Try remote. If the remote works, the problem is the

 

 

accessory.

Status (clear) 5

Close Edge

• Disconnect the edge sensor, photo beam, or any other

blinks

Terminal Shorted

accessory wired to this terminal.

 

 

• Try the remote. If the remote works, the problem is the

 

 

accessory.

Status (clear) 6

Open Edge

• Disconnect edge sensor, photo beam, or any other

blinks

Terminal Shorted

accessory wired to this terminal.

 

 

• Try the remote. If the remote works, the problem is the

 

 

accessory.

RF (yellow) Flickers

Receiving 318 MHz

• Normal operation when remote or wireless keypad is used.

 

RF

 

RF (yellow)OFF

No 318 MHz RF

• Battery in Remote

 

Received

• Program Remote

 

 

• Antenna Receiver Connections

 

 

• Antenna Receiver

 

 

 

Power (green)

AC or Solar Power

• Normal Operation

ON

Present

 

 

 

 

 

 

VOLTAGE READINGS

18 Vac Transformer

18.0 to 22.0 Vac

10 W Solar panel (single)

18.0 to 22.0 Vdc

In FULL SUN — measure voltage with the Solar Panel Disconnected.

12 V, 7 amp hour Battery

12.5 to 13.5 Vdc

or Two 12V, 7 amp hour Batteries if using solar power

 

Measure voltage at battery terminals with battery disconnected

Charging circuit

12.0 to 14.8 Vdc

Measure voltage at battery terminals with battery connected

GTO 4000XLS Instruction Manual © 01.10.12 25

Image 35
Contents 4000XLS For Your Records When You Know Multiply By To FindClass Rating Table of Contents Please Read This First 24/7 Troubleshooting Wizard http//support.gtoinc.comBefore YOU Begin to Install Your Automatic Gate Operator How To Manually Open and Close the Gate Important Safety InstructionsFor The Consumer Important Safety InstructionsAny control device Within gray area Never InstallInstall Warning Signs Entrapment Protection Required Safety Precautions for GatesSecondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ADC Swing Series Control Technical SpecificationsPower DriveZone Watts Determine Charging Option for Battery Transformer or SolarSolar Panel and Gate Activity Chart Before You BeginPrepare the Gate Check Direction of Gate SwingBracket BOX HB4000 4000XLS Parts ListTools Needed Materials You may Need for the InstallationPull-To-Open Gates Gate Opens into the Property Install the OperatorInstallation Overview Install the Post Bracket AssemblyStep Hair pin clip Check ClearanceAttach Operator Install Gate BracketInstall Closed Position Stop Plate Receiver cable Mount the Control Box and ReceiverMount the receiver Never Splice Wires Connect Operator Power CableConnect the Power Input Make sure the exposed wires do not touch each other Connect BatteryBe certain not to let the exposed wires touch each other To Close Control Board SettingsSet Closed Position Limit for Pull-To-Open Applications Set Auto Close Time Adjust the Stall Force Setting24/7 Troubleshooting Wizard http Support.gtoinc.com Program Your Personal Transmitter SettingDIP Switches DIP Switch SettingsInput Connections Connecting AccessoriesWiring Accessories Swinging gates shall not open into public access areas Push-To-Open Installation InformationInstall the Operator Set Control Board for Push-To-Open Setting the Open Position Limit Push-To-Open InstallationsColumn Installation Generation 3 Audible Feedback Troubleshooting GuideSymptom Diagnosis Check Voltage Readings Generation 3 Visual Feedback800am-700pm Monday-Friday EST Repair ServiceAccessories for 4000XLS Gooseneck Pedestal F100/F110 Residential Wireless Entry Intercom F3100MBCWireless Vehicle Sensor R4500 Wireless Driveway Alarm R4450Push Button Control RB101 Replacement Transformer RB570Photo Beams R4222 Pin Lock FM345Access Systems