GTO 12, R4854 01, 10 installation manual Install Closed Position Stop Plate

Page 20

Install Closed Position Stop Plate

The closed position stop plate helps to stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO Automatic Gate Lock [FM144]

Step 11

Remove hairpin, clevis pin, and 3/16” bushing from front mount and close the gate. Fasten the closed position stop plate to the end of the gate frame on the gate center-line (in line with the operator arm), but do not tighten it completely. Slide the closed position stop plate toward the post until they touch. Once you have moved the closed position stop

Gate Hinge

Closed Position

Stop Plate

The gate must open 110º (max.)

plate to the correct position, tighten its hardware completely.

Use the appropriate hardware for your type of gate (U-bolts for tube or chain link gate; wood or lag screws for wood gates, etc.). This hardware is not provided.

FRONT VIEW

Gate Post

Closed Position Stop Plate mounted on metal post with U-bolts.

Fence Post

TOP VIEW

Step 12

Return gate to the open position and reattach operator to gate.

C

L

Closed Position Stop Plate

Gate In Closed Position

10GTO 4000XLS Instruction Manual © 01.10.12

Image 20
Contents 4000XLS For Your Records When You Know Multiply By To FindClass Rating Table of Contents Please Read This First 24/7 Troubleshooting Wizard http//support.gtoinc.comBefore YOU Begin to Install Your Automatic Gate Operator Important Safety Instructions How To Manually Open and Close the GateImportant Safety Instructions For The ConsumerNever Install Any control device Within gray areaRequired Safety Precautions for Gates Install Warning Signs Entrapment ProtectionEntrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentDC Swing Series Technical Specifications PowerDrive ControlDetermine Charging Option for Battery Transformer or Solar Solar Panel and Gate Activity ChartBefore You Begin Zone WattsCheck Direction of Gate Swing Prepare the Gate4000XLS Parts List Bracket BOX HB4000Materials You may Need for the Installation Tools NeededInstall the Operator Installation OverviewInstall the Post Bracket Assembly Pull-To-Open Gates Gate Opens into the PropertyStep Check Clearance Hair pin clipInstall Gate Bracket Attach OperatorInstall Closed Position Stop Plate Receiver cable Mount the Control Box and ReceiverMount the receiver Connect Operator Power Cable Never Splice WiresConnect the Power Input Make sure the exposed wires do not touch each other Connect BatteryBe certain not to let the exposed wires touch each other To Close Control Board SettingsSet Closed Position Limit for Pull-To-Open Applications Adjust the Stall Force Setting Set Auto Close TimeProgram Your Personal Transmitter Setting 24/7 Troubleshooting Wizard http Support.gtoinc.comDIP Switch Settings DIP SwitchesConnecting Accessories Input ConnectionsWiring Accessories Swinging gates shall not open into public access areas Push-To-Open Installation InformationInstall the Operator Setting the Open Position Limit Push-To-Open Installations Set Control Board for Push-To-OpenColumn Installation Generation 3 Audible Feedback Troubleshooting GuideSymptom Diagnosis Check Generation 3 Visual Feedback Voltage ReadingsRepair Service 800am-700pm Monday-Friday ESTAccessories for 4000XLS Residential Wireless Entry Intercom F3100MBC Wireless Vehicle Sensor R4500Wireless Driveway Alarm R4450 Gooseneck Pedestal F100/F110Replacement Transformer RB570 Photo Beams R4222Pin Lock FM345 Push Button Control RB101Access Systems