GTO 10, R4854 01, 12 Please Read This First, 24/7 Troubleshooting Wizard http//support.gtoinc.com

Page 4

Please Read This First

®

, LLC

Thank you for purchasing a GTO/ACCESS SYSTEMS 4000XLS. When correctly installed and properly used, your 4000XLS operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your 4000XLS Automatic Gate Operator.

The 4000XLS operator is designed for installation on a pull-to-open single leaf gate. The gate must not exceed 20 feet in length nor weigh more than 1000 pounds* (please see Technical Specifications on page 1). The 4000XLS operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates.

Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct, stop, and blow fuses.

The 4000XLS can be installed on a push-to-open gate with the addition of the push-to-open bracket [R4KPTO].

The 4000XLS operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories are noted with the symbol.

The 4000XLS operator features adjustable stall force. This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction. The “MIN” setting means the gate will exert the minimum force on an obstruction before it stops and reverses direction.

The 4000XLS operator also has an adjustable auto-closefeature. It can be set to remain open from 3 to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully opens will cause it to close immediately. “OFF” is the factory setting; meaning the gate will stay open until you press the transmitter button (or keypad, etc.) again.

Please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/ACCESS SYSTEMS professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/ACCESS SYSTEMS dealer near you.

BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:

Read these instructions carefully and completely to become familiar with all parts and installation

steps. You must read the installation manual for detailed instructions on gate operator safety

and proper use of the gate operator.

24/7 Troubleshooting Wizard: http://support.gtoinc.com

GTO Accessories are noted with this symbol in this Installation Manual. Information about accessories can be found on page 27 and at www.gtoaccess.com.

iiGTO 4000XLS Instruction Manual © 01.10.12

Image 4
Contents 4000XLS Class Rating When You Know Multiply By To FindFor Your Records Table of Contents Before YOU Begin to Install Your Automatic Gate Operator 24/7 Troubleshooting Wizard http//support.gtoinc.comPlease Read This First Important Safety Instructions How To Manually Open and Close the GateImportant Safety Instructions For The ConsumerNever Install Any control device Within gray areaRequired Safety Precautions for Gates Install Warning Signs Entrapment ProtectionEntrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentDC Swing Series Technical Specifications PowerDrive ControlDetermine Charging Option for Battery Transformer or Solar Solar Panel and Gate Activity ChartBefore You Begin Zone WattsCheck Direction of Gate Swing Prepare the Gate4000XLS Parts List Bracket BOX HB4000Materials You may Need for the Installation Tools NeededInstall the Operator Installation OverviewInstall the Post Bracket Assembly Pull-To-Open Gates Gate Opens into the PropertyStep Check Clearance Hair pin clipInstall Gate Bracket Attach OperatorInstall Closed Position Stop Plate Mount the receiver Mount the Control Box and ReceiverReceiver cable Connect Operator Power Cable Never Splice WiresConnect the Power Input Be certain not to let the exposed wires touch each other Connect BatteryMake sure the exposed wires do not touch each other Set Closed Position Limit for Pull-To-Open Applications Control Board SettingsTo Close Adjust the Stall Force Setting Set Auto Close TimeProgram Your Personal Transmitter Setting 24/7 Troubleshooting Wizard http Support.gtoinc.comDIP Switch Settings DIP SwitchesConnecting Accessories Input ConnectionsWiring Accessories Install the Operator Push-To-Open Installation InformationSwinging gates shall not open into public access areas Setting the Open Position Limit Push-To-Open Installations Set Control Board for Push-To-OpenColumn Installation Symptom Diagnosis Check Troubleshooting GuideGeneration 3 Audible Feedback Generation 3 Visual Feedback Voltage ReadingsRepair Service 800am-700pm Monday-Friday ESTAccessories for 4000XLS Residential Wireless Entry Intercom F3100MBC Wireless Vehicle Sensor R4500Wireless Driveway Alarm R4450 Gooseneck Pedestal F100/F110Replacement Transformer RB570 Photo Beams R4222Pin Lock FM345 Push Button Control RB101Access Systems