Troubleshooting Guide
If your gate operator does not function properly after it is installed, use this guide before calling the GTO Service Department.
Generation 3 Audible Feedback
SYMPTOM | DIAGNOSIS | CHECK: |
|
|
|
1 short beep upon | Circuit Board | • Normal Operation |
power up | Powered Up & |
|
| Ready |
|
|
|
|
1 short beep upon | Blown Fuse | • Fuse |
activation | Low or Bad Battery | • Battery Under Load |
| • Battery Harness Connections | |
| Loose Battery | |
|
| |
| Connection |
|
Continuous | Circuit Board | • Path of Gate |
Uninterrupted | Senses an | • Gate for Level and Plumb |
Alarm | Obstruction | • Stall Force Adjustment |
|
| • Disconnect Safety Devices |
|
| • Rev Counter |
|
|
|
1 beep with 10 | Low Battery | • Fuses |
seconds off | Condition | • Battery Harness Connections |
|
| • Battery Under Load |
|
|
|
1 beep then 2 | Master Motor | • Connections to Master Inputs |
beeps | Terminals Shorted | • Master Arm Power Cable |
|
| • Motor |
|
| • Circuit Board |
|
|
|
1 beep with 2 | Master Arm Limit | • Connections to Master Inputs |
seconds off | Switch Error | • Master Arm Power Cable |
|
|
|
3 beeps with 2 | Master Arm Rev | • Connections to Master Inputs |
seconds off | Counter Error | • Master Arm Power Cable |
|
| • Rev Counter |
|
|
|