GTO R4854 01 Secondary Means of Protection Against Entrapment, Entrapment Alarm UL 325 30A.1.1A

Page 9

IMPORTANT SAFETY INSTRUCTIONS

Secondary Means of Protection Against Entrapment

As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. The 4000XLS utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the 4000XLS has provisions for the connection of Type B1 or B2 protection to be used as the secondary type of entrapment protection, if desired.

1.For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor– Type B1) in accordance with UL 325 (51.8.4 [h]):

A.Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of application.

B.Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.

C.One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.

2.For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):

A.One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system.

B.A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.

C.A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.

You may want to consider adding photo beams to your installation. GTO Photo Beams [R4222] provide a “non contact” means of entrapment protection.

Leading Edge Contact Sensor

 

 

on both sides of the gate

 

 

Vehicular Gate

 

Photo Beam

Post Edge Contact Sensor

Photo Beam

Bottom Edge Contact Sensor

 

on both sides of the gate

on both sides of the gate

 

ENTRAPMENT ALARM (UL 325; 30A.1.1A)

The 4000XLS Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.

GTO 4000XLS Instruction Manual © 01.10.12 vii

Image 9
Contents 4000XLS When You Know Multiply By To Find Class RatingFor Your Records Table of Contents 24/7 Troubleshooting Wizard http//support.gtoinc.com Before YOU Begin to Install Your Automatic Gate OperatorPlease Read This First How To Manually Open and Close the Gate Important Safety InstructionsFor The Consumer Important Safety InstructionsAny control device Within gray area Never InstallInstall Warning Signs Entrapment Protection Required Safety Precautions for GatesSecondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ADC Swing Series Power Technical SpecificationsDrive ControlSolar Panel and Gate Activity Chart Determine Charging Option for Battery Transformer or SolarBefore You Begin Zone WattsPrepare the Gate Check Direction of Gate SwingBracket BOX HB4000 4000XLS Parts ListTools Needed Materials You may Need for the InstallationInstallation Overview Install the OperatorInstall the Post Bracket Assembly Pull-To-Open Gates Gate Opens into the PropertyStep Hair pin clip Check ClearanceAttach Operator Install Gate BracketInstall Closed Position Stop Plate Mount the Control Box and Receiver Mount the receiverReceiver cable Never Splice Wires Connect Operator Power CableConnect the Power Input Connect Battery Be certain not to let the exposed wires touch each otherMake sure the exposed wires do not touch each other Control Board Settings Set Closed Position Limit for Pull-To-Open ApplicationsTo Close Set Auto Close Time Adjust the Stall Force Setting24/7 Troubleshooting Wizard http Support.gtoinc.com Program Your Personal Transmitter SettingDIP Switches DIP Switch SettingsInput Connections Connecting AccessoriesWiring Accessories Push-To-Open Installation Information Install the OperatorSwinging gates shall not open into public access areas Set Control Board for Push-To-Open Setting the Open Position Limit Push-To-Open InstallationsColumn Installation Troubleshooting Guide Symptom Diagnosis CheckGeneration 3 Audible Feedback Voltage Readings Generation 3 Visual Feedback800am-700pm Monday-Friday EST Repair ServiceAccessories for 4000XLS Wireless Vehicle Sensor R4500 Residential Wireless Entry Intercom F3100MBCWireless Driveway Alarm R4450 Gooseneck Pedestal F100/F110Photo Beams R4222 Replacement Transformer RB570Pin Lock FM345 Push Button Control RB101Access Systems