GTO 10, R4854 01, 12 installation manual DC Swing Series

Page 10

IMPORTANT SAFETY INSTRUCTIONS

!

Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate).

DC SWING SERIES

Conforms to UL 325 STANDARDS

Maximum Gate: 1000 lb. (453.5 kg); 20 ft. (6.1 m)

CUS Voltage: 12 Vdc; Frequency: 0 Hz; Power: 60 W

LIS TED Class I Vehicular Swing Gate Operator.

9901178

Serial Number: XXXXXX

 

 

 

TO MANUALLY OPEN AND CLOSE THE GATE:

1.Turn control box power switch OFF.

2.Disconnect front or rear mount.

3.Pull operator away from front or rear mounts.

Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.

XXXXXXGates That Open, LLC • Tallahassee, Florida USA

Product identification and manual operation instruction label (1) installed on right side of control box.

Logo and warning labels (2) installed on each side of operator housing.

viiiGTO 4000XLS Instruction Manual © 01.10.12

Image 10
Contents 4000XLS Class Rating When You Know Multiply By To FindFor Your Records Table of Contents Before YOU Begin to Install Your Automatic Gate Operator 24/7 Troubleshooting Wizard http//support.gtoinc.comPlease Read This First Important Safety Instructions How To Manually Open and Close the GateImportant Safety Instructions For The ConsumerNever Install Any control device Within gray areaRequired Safety Precautions for Gates Install Warning Signs Entrapment ProtectionEntrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentDC Swing Series Drive Technical SpecificationsPower ControlBefore You Begin Determine Charging Option for Battery Transformer or SolarSolar Panel and Gate Activity Chart Zone WattsCheck Direction of Gate Swing Prepare the Gate4000XLS Parts List Bracket BOX HB4000Materials You may Need for the Installation Tools NeededInstall the Post Bracket Assembly Install the OperatorInstallation Overview Pull-To-Open Gates Gate Opens into the PropertyStep Check Clearance Hair pin clipInstall Gate Bracket Attach OperatorInstall Closed Position Stop Plate Mount the receiver Mount the Control Box and ReceiverReceiver cable Connect Operator Power Cable Never Splice WiresConnect the Power Input Be certain not to let the exposed wires touch each other Connect BatteryMake sure the exposed wires do not touch each other Set Closed Position Limit for Pull-To-Open Applications Control Board SettingsTo Close Adjust the Stall Force Setting Set Auto Close TimeProgram Your Personal Transmitter Setting 24/7 Troubleshooting Wizard http Support.gtoinc.comDIP Switch Settings DIP SwitchesConnecting Accessories Input ConnectionsWiring Accessories Install the Operator Push-To-Open Installation InformationSwinging gates shall not open into public access areas Setting the Open Position Limit Push-To-Open Installations Set Control Board for Push-To-OpenColumn Installation Symptom Diagnosis Check Troubleshooting GuideGeneration 3 Audible Feedback Generation 3 Visual Feedback Voltage ReadingsRepair Service 800am-700pm Monday-Friday ESTAccessories for 4000XLS Wireless Driveway Alarm R4450 Residential Wireless Entry Intercom F3100MBCWireless Vehicle Sensor R4500 Gooseneck Pedestal F100/F110Pin Lock FM345 Replacement Transformer RB570Photo Beams R4222 Push Button Control RB101Access Systems