Mount the Control Box and Receiver

Step 1

Mount the control box using the screws (provided) or another secure mounting method. The control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent electrical interference.

Step 2

Temporarily mount the receiver at this time. You will need to use the transmitter (page 17) to check the range of the receiver before permanently mounting it. You may have to try different locations before permanently mounting the receiver. The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference.

Mount the receiver:

Ensuring a line-of-sight between transmitter and antenna.

At least 3 feet away from AC voltage.

As high as possible for optimum range.

DO NOT mount receiver upside down.

DO NOT mount receiver on metal fence or post (this will decrease signal range). If attaching receiver to metal fence, you should mount receiver on a piece of wood attached to the fence (see illustration).

The receiver cable:

Cable length is 10 ft. (receivers with longer cables are available as special order items; call the GTO Sales Department).

NEVER splice receiver cable!

Run the receiver cable through PVC conduit to protect it from damage.

DO NOT run cable in conduit containing AC wiring.

Use mounting

 

 

FUSE

 

 

 

 

25

BATT+

 

 

 

 

 

BATT-

 

holes and screws

 

 

 

 

 

provided to mount

INPUTS

OUTPUTS

 

 

 

control box to a

POWER

CONTROL

 

 

 

 

AUX

SLAVE INPUTS

MASTER INPUTS

RECEIVER

 

 

RLY

SLAVE CABLE

MASTER CABLE

CONTROL INPUTS

secure surface.

 

 

 

 

 

Receiver mounted

on piece of wood

This device complies with FCC rules Part 15. Operation is subject to the following conditions:

1.This device may not cause harmful interference.

2.This device must accept an interference that may cause undesired operation.

Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

GTO 4000XLS Instruction Manual © 01.10.12 11

Image 21
Contents 4000XLS When You Know Multiply By To Find Class RatingFor Your Records Table of Contents 24/7 Troubleshooting Wizard http//support.gtoinc.com Before YOU Begin to Install Your Automatic Gate OperatorPlease Read This First How To Manually Open and Close the Gate Important Safety InstructionsFor The Consumer Important Safety InstructionsAny control device Within gray area Never InstallInstall Warning Signs Entrapment Protection Required Safety Precautions for GatesSecondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ADC Swing Series Power Technical SpecificationsDrive ControlSolar Panel and Gate Activity Chart Determine Charging Option for Battery Transformer or SolarBefore You Begin Zone WattsPrepare the Gate Check Direction of Gate SwingBracket BOX HB4000 4000XLS Parts ListTools Needed Materials You may Need for the InstallationInstallation Overview Install the OperatorInstall the Post Bracket Assembly Pull-To-Open Gates Gate Opens into the PropertyStep Hair pin clip Check ClearanceAttach Operator Install Gate BracketInstall Closed Position Stop Plate Mount the Control Box and Receiver Mount the receiverReceiver cable Never Splice Wires Connect Operator Power CableConnect the Power Input Connect Battery Be certain not to let the exposed wires touch each otherMake sure the exposed wires do not touch each other Control Board Settings Set Closed Position Limit for Pull-To-Open ApplicationsTo Close Set Auto Close Time Adjust the Stall Force Setting24/7 Troubleshooting Wizard http Support.gtoinc.com Program Your Personal Transmitter SettingDIP Switches DIP Switch SettingsInput Connections Connecting AccessoriesWiring Accessories Push-To-Open Installation Information Install the OperatorSwinging gates shall not open into public access areas Set Control Board for Push-To-Open Setting the Open Position Limit Push-To-Open InstallationsColumn Installation Troubleshooting Guide Symptom Diagnosis CheckGeneration 3 Audible Feedback Voltage Readings Generation 3 Visual Feedback800am-700pm Monday-Friday EST Repair ServiceAccessories for 4000XLS Wireless Vehicle Sensor R4500 Residential Wireless Entry Intercom F3100MBCWireless Driveway Alarm R4450 Gooseneck Pedestal F100/F110Photo Beams R4222 Replacement Transformer RB570Pin Lock FM345 Push Button Control RB101Access Systems