Graco EQ300C manual Connecting the Blast Hose and Air Hose

Page 10

Operation

Connecting the Blast Hose and Air Hose

3.Open the air supply valve (125 psi, 8.6 Bar, 0.86 MPa maximum). If necessary, use a regulator in the supply air line to meet these specifications.

1.Always purge the air supply hose 15–20 seconds before connecting the air supply hose from the compressor (or on-site compressed air source) to the panel. Make sure all debris is cleared from the hose.

 

FF

R

UN

T

O

 

AR

 

ST

 

 

 

 

 

2.Connect an appropriately sized air supply hose to the air inlet. See Technical Specifications, page 45.

NOTE: Make sure the air supply meets the appropriate air flow requirements. See Technical Specifications, page 45.

4.Connect the blast hose, hose restraints, control hoses, and coupler pins.

NOTE: Make sure to properly install hose restraints and coupler pins to the quick-coupler and the air line. If the holes on the quick-coupler do not align, there is something wrong and the two couplers are not compatible. DO NOT TURN ON THE AIR. Seek help to get the situation resolved.

ti24706a

NOTE: If you are using an electric blast control, check all of the electrical connections from the panel to the blast control.

NOTICE

Make sure no electrical connections will be exposed to water. Exposure to water could cause a short circuit and damage the equipment.

10

334667B

Image 10
Contents Important Safety Instructions EcoQuip Vapor Abrasive Blast SystemModels Related ManualsDust and Debris Hazard Burn Hazard Metric OEM System GuidelinesCompressor Size and Hose Length Minimum ID Metric System Component Identification EQ300C and EQ600CKey DataTrak ControlsDataTrak see DataTrak Controls, Pressure Relief Procedure Checklist Before Starting OperationConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting Tips Blasting on Higher SurfacesWood Metering Valve SettingsGrit Size Blast Pressure Abrasive Dose Blast Angle General SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment See Cleaning the Auto-Vent Valve, TroubleshootingProblem Cause Solution See Repairing the Main Air RegulatorProcedure see Shutting Down, See Setting Up the Equipment,See Repairing the Diaphragm Valve Intact. See Hose Schematic,See Pressure Relief Procedure, Properly. See Hose Schematic,Metering Valve Settings, Setting Up the Equipment,If flushing does not solve the problem, see Troubleshooting Examples Checking for LeaksPneumatic Blast Control Circuit Perform Pressure Relief Procedure, Repairing the Main Air RegulatorRepair Flushing the Diaphragm Valve Repairing the Diaphragm Valve Perform the Pressure Relief Procedure,Cleaning the Auto-Vent Valve Replace Battery Replacing the DataTrak BatteryApproved Batteries Replace Fuse Replacing the DataTrak FuseApproved Fuses DataTrak Part Series Letter Fuse Required Parts EQ300C and EQ600CEQ300C and EQ600C Parts List Pressure POTEnclosure Enclosure Parts List Part Description QtyPressure Pot Pressure Pot Parts ListRef. Part Description Qty Hose Schematic EcoQuip Trailer Systems Vapor Abrasive Blast Systems and AccessoriesEcoQuip Skid Systems Model Series BrakesModel Mobile/Skid UnitsTrailer Units Model DescriptionNozzles HosesModel Description Type Length Blast Control Other Accessories Common Spare PartsDimensions EQ300S Technical SpecificationsEQ600S Graco Extended Warranty for EcoQuip Components Graco Information