Graco EQ300C manual If flushing does not solve the problem, see

Page 25

 

 

Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

A strong hose recoil occurs

The unit is not on a level surface.

Place the unit on a level surface. If this

frequently when the blast

 

is impossible, the Auto-Vent must be on

control switch is engaged.

 

the higher side of the unit.

 

The initial pot pressure is not set

Confirm that the auto-vent valve is

 

correctly.

working and set initial pot pressure 30

 

 

psi (2.0 bar, 0.20 MPa) above the blast

 

 

pressure.

 

The Auto-Vent is malfunctioning.

Perform auto-vent clean-

 

 

ing procedure (see

 

 

Cleaning the Auto-Vent Valve, page 31).

 

The diaphragm needs to be

Perform the diaphragm

 

flushed.

flush procedure (see

 

 

Flushing the Diaphragm Valve, page 29).

 

 

If flushing does not solve the problem, see

 

 

Repairing the Diaphragm Valve, page 30.

334667B

25

Image 25
Contents EcoQuip Vapor Abrasive Blast System Important Safety InstructionsRelated Manuals ModelsDust and Debris Hazard Burn Hazard Metric OEM System GuidelinesCompressor Size and Hose Length Minimum ID Metric EQ300C and EQ600C System Component IdentificationKey DataTrak ControlsDataTrak see DataTrak Controls, Pressure Relief Procedure Operation Checklist Before StartingConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting on Higher Surfaces Blasting TipsGrit Size Blast Pressure Abrasive Dose Blast Angle General Metering Valve SettingsWood SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment Problem Cause Solution TroubleshootingSee Cleaning the Auto-Vent Valve, See Repairing the Main Air RegulatorSee Repairing the Diaphragm Valve See Setting Up the Equipment,Procedure see Shutting Down, Intact. See Hose Schematic,Metering Valve Settings, Properly. See Hose Schematic,See Pressure Relief Procedure, Setting Up the Equipment,If flushing does not solve the problem, see Checking for Leaks Troubleshooting ExamplesPneumatic Blast Control Circuit Perform Pressure Relief Procedure, Repairing the Main Air RegulatorRepair Flushing the Diaphragm Valve Perform the Pressure Relief Procedure, Repairing the Diaphragm ValveCleaning the Auto-Vent Valve Replace Battery Replacing the DataTrak BatteryApproved Batteries Replace Fuse Replacing the DataTrak FuseApproved Fuses DataTrak Part Series Letter Fuse Required EQ300C and EQ600C PartsPressure POT EQ300C and EQ600C Parts ListEnclosure Part Description Qty Enclosure Parts ListPressure Pot Pressure Pot Parts ListRef. Part Description Qty Hose Schematic EcoQuip Skid Systems Vapor Abrasive Blast Systems and AccessoriesEcoQuip Trailer Systems Model Series BrakesTrailer Units Mobile/Skid UnitsModel Model DescriptionNozzles HosesModel Description Type Length Blast Control Common Spare Parts Other AccessoriesDimensions EQ300S Technical SpecificationsEQ600S Graco Information Graco Extended Warranty for EcoQuip Components