Graco EQ300C manual See Refilling the Pot with Abrasive, See Setting Up the Equipment

Page 23

 

 

Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

No abrasive flows from the

The pot does not have a sufficient

See Refilling the Pot with Abrasive, page

nozzle during blast mode.

amount of abrasive.

18.

 

The system is not properly set up.

See Setting Up the Equipment, page 11.

 

 

Make sure the pot pressure is properly

 

 

set. The pot pressure must be set 30

 

 

psi above the blast pressure. Make sure

 

 

the selector valve is set to BLAST. The

 

 

abrasive ball valve must be open. The

 

 

abrasive metering valve must be at least

 

 

1/8 turn open.

 

There is an obstruction in the

See Flushing the Diaphragm Valve, page

 

media circuit.

29.

 

The diaphragm valve is not

See Repairing the Diaphragm Valve,

 

working.

page 30.

 

There is blockage inside the pot or

Make sure the ball valve is closed, then

 

inside the abrasive hose between

disconnect the cam-lock coupler. Open

 

the pot and the panel.

the abrasive ball valve slightly and make

 

 

sure abrasive is flowing form the abrasive

 

 

hose. If not, follow the shut down

 

 

procedure (see Shutting Down, page 19).

 

 

Thoroughly flush the pot and the media

 

 

hose after draining media and water.

No blast air flow when the

The blast regulator is not adjusted

Adjust the blast regulator to the desired

blast control is engaged.

to the correct pressure.

pressure while the blast control is

The water pump cycles

 

engaged.

while the blast control

 

 

The tubing from the main

Confirm that the tubing from the blast

engaged.

air regulator is not properly

regulator to the main air regulator is

 

 

connected.

intact. See Hose Schematic, page 39.

 

 

 

 

The blast air regulator is

Replace the blast air regulator (Kit

 

malfunctioning.

17C625).

 

The main air regulator is

See Repairing the Main Air Regulator,

 

malfunctioning.

page 28 (EQ600 – Kit 17C131, EQ300

 

 

– Kit 17C129).

No blast air flow when the

The air supply is inadequate.

Make sure the air inlet pressure gauge

blast control is engaged.

 

reads 100-125 psi. If the gauge does

The water pump does not

 

not read 100–125 psi, check the air

cycle while the blast control

 

compressor for proper setup.

engaged.

 

 

The Emergency Stop is engaged.

Disengage the Emergency Stop.

 

 

The electric blast control circuit is

Inspect the hose cable for damaged or

 

malfunctioning.

shorted wiring. Check the battery and

 

 

control panel connections. Make sure the

 

 

DC power source is 12V. Check the 3A

 

 

fuse inside the control panel, and replace

 

 

it if necessary. Check the current flow in

 

 

the circuit. If current exists, replace the

 

 

relay (EQ5179).

334667B

23

Image 23
Contents EcoQuip Vapor Abrasive Blast System Important Safety InstructionsRelated Manuals ModelsDust and Debris Hazard Burn Hazard Compressor Size and Hose Length Minimum ID Metric OEM System GuidelinesMetric EQ300C and EQ600C System Component IdentificationDataTrak see DataTrak Controls, DataTrak ControlsKey Pressure Relief Procedure Operation Checklist Before StartingConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting on Higher Surfaces Blasting TipsSteel Metering Valve SettingsGrit Size Blast Pressure Abrasive Dose Blast Angle General WoodUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment See Repairing the Main Air Regulator TroubleshootingProblem Cause Solution See Cleaning the Auto-Vent Valve,Intact. See Hose Schematic, See Setting Up the Equipment,See Repairing the Diaphragm Valve Procedure see Shutting Down,Setting Up the Equipment, Properly. See Hose Schematic,Metering Valve Settings, See Pressure Relief Procedure,If flushing does not solve the problem, see Checking for Leaks Troubleshooting ExamplesPneumatic Blast Control Circuit Repair Repairing the Main Air RegulatorPerform Pressure Relief Procedure, Flushing the Diaphragm Valve Perform the Pressure Relief Procedure, Repairing the Diaphragm ValveCleaning the Auto-Vent Valve Approved Batteries Replacing the DataTrak BatteryReplace Battery Approved Fuses DataTrak Part Series Letter Fuse Required Replacing the DataTrak FuseReplace Fuse EQ300C and EQ600C PartsPressure POT EQ300C and EQ600C Parts ListEnclosure Part Description Qty Enclosure Parts ListRef. Part Description Qty Pressure Pot Parts ListPressure Pot Hose Schematic Model Series Brakes Vapor Abrasive Blast Systems and AccessoriesEcoQuip Skid Systems EcoQuip Trailer SystemsModel Description Mobile/Skid UnitsTrailer Units ModelModel Description Type Length Blast Control HosesNozzles Common Spare Parts Other AccessoriesDimensions EQ600S Technical SpecificationsEQ300S Graco Information Graco Extended Warranty for EcoQuip Components