| Troubleshooting | |
|
|
| |
Problem | Cause | Solution | |
|
|
| |
No abrasive flows from the | The pot does not have a sufficient | See Refilling the Pot with Abrasive, page | |
nozzle during blast mode. | amount of abrasive. | 18. | |
| The system is not properly set up. | See Setting Up the Equipment, page 11. | |
|
| Make sure the pot pressure is properly | |
|
| set. The pot pressure must be set 30 | |
|
| psi above the blast pressure. Make sure | |
|
| the selector valve is set to BLAST. The | |
|
| abrasive ball valve must be open. The | |
|
| abrasive metering valve must be at least | |
|
| 1/8 turn open. | |
| There is an obstruction in the | See Flushing the Diaphragm Valve, page | |
| media circuit. | 29. | |
| The diaphragm valve is not | See Repairing the Diaphragm Valve, | |
| working. | page 30. | |
| There is blockage inside the pot or | Make sure the ball valve is closed, then | |
| inside the abrasive hose between | disconnect the | |
| the pot and the panel. | the abrasive ball valve slightly and make | |
|
| sure abrasive is flowing form the abrasive | |
|
| hose. If not, follow the shut down | |
|
| procedure (see Shutting Down, page 19). | |
|
| Thoroughly flush the pot and the media | |
|
| hose after draining media and water. | |
No blast air flow when the | The blast regulator is not adjusted | Adjust the blast regulator to the desired | |
blast control is engaged. | to the correct pressure. | pressure while the blast control is | |
The water pump cycles |
| engaged. | |
while the blast control |
|
| |
The tubing from the main | Confirm that the tubing from the blast | ||
engaged. | |||
air regulator is not properly | regulator to the main air regulator is | ||
| |||
| connected. | intact. See Hose Schematic, page 39. | |
|
|
| |
| The blast air regulator is | Replace the blast air regulator (Kit | |
| malfunctioning. | 17C625). | |
| The main air regulator is | See Repairing the Main Air Regulator, | |
| malfunctioning. | page 28 (EQ600 – Kit 17C131, EQ300 | |
|
| – Kit 17C129). | |
No blast air flow when the | The air supply is inadequate. | Make sure the air inlet pressure gauge | |
blast control is engaged. |
| reads | |
The water pump does not |
| not read | |
cycle while the blast control |
| compressor for proper setup. | |
engaged. |
|
| |
The Emergency Stop is engaged. | Disengage the Emergency Stop. | ||
| |||
| The electric blast control circuit is | Inspect the hose cable for damaged or | |
| malfunctioning. | shorted wiring. Check the battery and | |
|
| control panel connections. Make sure the | |
|
| DC power source is 12V. Check the 3A | |
|
| fuse inside the control panel, and replace | |
|
| it if necessary. Check the current flow in | |
|
| the circuit. If current exists, replace the | |
|
| relay (EQ5179). |
334667B | 23 |