Graco EQ300C manual Repairing the Main Air Regulator, Perform Pressure Relief Procedure

Page 28

Repair

Repair

Repairing the Main Air Regulator

NOTE: Repair parts are available in Kit 17C131 (EQ600) or Kit 17C129 (EQ300).

1.Perform Pressure Relief Procedure, page 8 .

2.Make sure all of the air pressure is relieved in the unit. Remove the water separator filter for access to the piston cover and return spring.

3.Use a crescent wrench that can open to 2 in. (5 cm) to unscrew the piston cover.

NOTE: There is a spring inside this cover.

4.Unscrew the diaphragm cover for access to the diaphragm and to the end of the piston shaft.

5.Remove the diaphragm and inspect for any cracks or tears. Replace the diaphragm if necessary.

6.Carefully remove the spring and piston assembly, then clean out any debris in the body of the regulator.

7.Push the piston shaft and remove the piston from the opposite end of the regulator housing.

8.Inspect the piston for any foreign matter that may have been the cause for the piston to stay open.

9.Inspect for any damage to the piston shaft where it interacts with the diaphragm cup.

NOTE: Excessive wear here indicates the main check valve is not sealing. Contact your distributor if this happens.

28

334667B

Image 28
Contents Important Safety Instructions EcoQuip Vapor Abrasive Blast SystemModels Related ManualsDust and Debris Hazard Burn Hazard Metric OEM System GuidelinesCompressor Size and Hose Length Minimum ID Metric System Component Identification EQ300C and EQ600CKey DataTrak ControlsDataTrak see DataTrak Controls, Pressure Relief Procedure Checklist Before Starting OperationConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting Tips Blasting on Higher SurfacesMetering Valve Settings Grit Size Blast Pressure Abrasive Dose Blast Angle GeneralWood SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment Troubleshooting Problem Cause SolutionSee Cleaning the Auto-Vent Valve, See Repairing the Main Air RegulatorSee Setting Up the Equipment, See Repairing the Diaphragm ValveProcedure see Shutting Down, Intact. See Hose Schematic,Properly. See Hose Schematic, Metering Valve Settings,See Pressure Relief Procedure, Setting Up the Equipment,If flushing does not solve the problem, see Troubleshooting Examples Checking for LeaksPneumatic Blast Control Circuit Perform Pressure Relief Procedure, Repairing the Main Air RegulatorRepair Flushing the Diaphragm Valve Repairing the Diaphragm Valve Perform the Pressure Relief Procedure,Cleaning the Auto-Vent Valve Replace Battery Replacing the DataTrak BatteryApproved Batteries Replace Fuse Replacing the DataTrak FuseApproved Fuses DataTrak Part Series Letter Fuse Required Parts EQ300C and EQ600CEQ300C and EQ600C Parts List Pressure POTEnclosure Enclosure Parts List Part Description QtyPressure Pot Pressure Pot Parts ListRef. Part Description Qty Hose Schematic Vapor Abrasive Blast Systems and Accessories EcoQuip Skid SystemsEcoQuip Trailer Systems Model Series BrakesMobile/Skid Units Trailer UnitsModel Model DescriptionNozzles HosesModel Description Type Length Blast Control Other Accessories Common Spare PartsDimensions EQ300S Technical SpecificationsEQ600S Graco Extended Warranty for EcoQuip Components Graco Information