Graco EQ300C manual 0 0 0 8 8 0 0 0 3

Page 14

Operation

20. Open the abrasive ball valve.

NOTE: Make sure the pot pressure returns to the initial setting (it will not return to the initial setting if the metering valve is closed).

21.Engage the blast control switch and begin blasting.

NOTE: You may have to wait 1–2 minutes for the abrasive material to reach the nozzle.

NOTE: Pot pressure and blast pressure should equalize during blasting. Only set pot pressure with the abrasive ball valve closed. Never adjust pot pressure while blasting.

22.Slowly adjust the abrasive meter valve while the abrasive is blasting from the nozzle. Typical adjustment ranges from 1/8 to 1/4 turn open.

NOTE: The DataTrak can be used to assist in setting the pump cycle rate. Optimal abrasive media consumption typically occurs with the cycle rate set at 7–10 cycles per minute.

0 0 0 0 0 8 8 0 0 0 3 8

9

NOTE: Use a piece of test material similar to what you will be blasting.

NOTE: Always start as gently as possible and then increase the blast force as necessary to clean without doing any damage to the substrate. When properly set, the pump should cycle 7-10 times per minute. High production rate users may need to increase cycle rate above 10 cycles per minute.

NOTE: Close the abrasive ball valve whenever you stop blasting for more than 2-3 minutes. This will help to extend the service life of the diaphragm valve.

14

334667B

Image 14
Contents Important Safety Instructions EcoQuip Vapor Abrasive Blast SystemModels Related ManualsDust and Debris Hazard Burn Hazard Compressor Size and Hose Length Minimum ID Metric OEM System GuidelinesMetric System Component Identification EQ300C and EQ600CDataTrak see DataTrak Controls, DataTrak ControlsKey Pressure Relief Procedure Checklist Before Starting OperationConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting Tips Blasting on Higher SurfacesWood Metering Valve SettingsGrit Size Blast Pressure Abrasive Dose Blast Angle General SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment See Cleaning the Auto-Vent Valve, TroubleshootingProblem Cause Solution See Repairing the Main Air RegulatorProcedure see Shutting Down, See Setting Up the Equipment,See Repairing the Diaphragm Valve Intact. See Hose Schematic,See Pressure Relief Procedure, Properly. See Hose Schematic,Metering Valve Settings, Setting Up the Equipment,If flushing does not solve the problem, see Troubleshooting Examples Checking for LeaksPneumatic Blast Control Circuit Repair Repairing the Main Air RegulatorPerform Pressure Relief Procedure, Flushing the Diaphragm Valve Repairing the Diaphragm Valve Perform the Pressure Relief Procedure,Cleaning the Auto-Vent Valve Approved Batteries Replacing the DataTrak BatteryReplace Battery Approved Fuses DataTrak Part Series Letter Fuse Required Replacing the DataTrak FuseReplace Fuse Parts EQ300C and EQ600CEQ300C and EQ600C Parts List Pressure POTEnclosure Enclosure Parts List Part Description QtyRef. Part Description Qty Pressure Pot Parts ListPressure Pot Hose Schematic EcoQuip Trailer Systems Vapor Abrasive Blast Systems and AccessoriesEcoQuip Skid Systems Model Series BrakesModel Mobile/Skid UnitsTrailer Units Model DescriptionModel Description Type Length Blast Control HosesNozzles Other Accessories Common Spare PartsDimensions EQ600S Technical SpecificationsEQ300S Graco Extended Warranty for EcoQuip Components Graco Information