Graco EQ300C manual Blasting Tips, Blasting on Higher Surfaces

Page 15

Blasting Tips

When first learning the effects of the blaster, get a better understanding of the results by starting at a shallow angle (closer to 0° than to 90°) and keep the nozzle approximately 16 in. (40 cm) from the application. Observe the results, then reduce the distance, steepen the angle, and adjust the blast regulator.

As the blast pressure is increased, slowly adjust the metering valve and watch the DataTrak to achieve 7-10 pump cycles per minute. See DataTrak Controls, page 7 .

NOTE: The heavier and smaller the abrasive particle (i.e. 80-grit), the more aggressive the results.

Operation

Blasting on Higher Surfaces

When blasting on a surface higher than the equipment, make sure that there is a length of blast hose on the ground equal to 10-20% of the height. The hose on the ground prevents unspent abrasive in the hose from back-filling the internal plumbing of the panel.

For example: When blasting 50 feet (15 m) straight up, use at least 10 feet (3 m) of blast hose on the ground before the blast hose goes up to the blasting height.

334667B

15

Image 15
Contents EcoQuip Vapor Abrasive Blast System Important Safety InstructionsRelated Manuals ModelsDust and Debris Hazard Burn Hazard OEM System Guidelines MetricCompressor Size and Hose Length Minimum ID Metric EQ300C and EQ600C System Component IdentificationDataTrak Controls KeyDataTrak see DataTrak Controls, Pressure Relief Procedure Operation Checklist Before StartingConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting on Higher Surfaces Blasting TipsSteel Metering Valve SettingsGrit Size Blast Pressure Abrasive Dose Blast Angle General WoodUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment See Repairing the Main Air Regulator TroubleshootingProblem Cause Solution See Cleaning the Auto-Vent Valve,Intact. See Hose Schematic, See Setting Up the Equipment,See Repairing the Diaphragm Valve Procedure see Shutting Down,Setting Up the Equipment, Properly. See Hose Schematic,Metering Valve Settings, See Pressure Relief Procedure,If flushing does not solve the problem, see Checking for Leaks Troubleshooting ExamplesPneumatic Blast Control Circuit Repairing the Main Air Regulator Perform Pressure Relief Procedure,Repair Flushing the Diaphragm Valve Perform the Pressure Relief Procedure, Repairing the Diaphragm ValveCleaning the Auto-Vent Valve Replacing the DataTrak Battery Replace BatteryApproved Batteries Replacing the DataTrak Fuse Replace FuseApproved Fuses DataTrak Part Series Letter Fuse Required EQ300C and EQ600C PartsPressure POT EQ300C and EQ600C Parts ListEnclosure Part Description Qty Enclosure Parts ListPressure Pot Parts List Pressure PotRef. Part Description Qty Hose Schematic Model Series Brakes Vapor Abrasive Blast Systems and AccessoriesEcoQuip Skid Systems EcoQuip Trailer SystemsModel Description Mobile/Skid UnitsTrailer Units ModelHoses NozzlesModel Description Type Length Blast Control Common Spare Parts Other AccessoriesDimensions Technical Specifications EQ300SEQ600S Graco Information Graco Extended Warranty for EcoQuip Components