Graco EQ300C manual See Pneumatic Blast Control Circuit, Properly. See Hose Schematic

Page 24

Troubleshooting

Problem

Cause

Solution

 

 

 

 

The pneumatic blast control circuit

See Pneumatic Blast Control Circuit,

 

is malfunctioning.

page 27.

The blast control is not

The main air regulator is stuck

See Repairing the Main Air Regulator,

engaged but blasting still

open.

page 28 (EQ600 – Kit 17C131, EQ300

occurs.

 

– Kit 17C129).

 

The blast control tubing is not

Ensure air tubing is routed and connected

 

connected properly.

properly. See Hose Schematic, page 39.

 

Electric blast control circuit is

Inspect hose cable for damaged or

 

malfunctioning.

shorted wiring. Check battery and control

 

 

panel connections. Ensure DC power

 

 

source is 12V. Check 3A fuse inside

 

 

control panel and replace it if necessary.

 

 

Check current flow in circuit, if current

 

 

exists, replace relay (EQ5179).

 

Pneumatic blast control circuit is

See Pneumatic Blast Control Circuit,

 

malfunctioning.

page 27.

The blast spray pattern is

Incorrect abrasive is being used.

Use the correct abrasive. See

irregular.

 

Metering Valve Settings, page 16.

 

The pot does not have a sufficient

Refill the pot with abrasive. See

 

amount of abrasive.

Refilling the Pot with Abrasive, page 18.

 

The pot pressure setting is

Perform the pressure relief procedure

 

incorrect.

(see Pressure Relief Procedure, page 8 )

 

 

and reset pot pressure (see

 

 

Setting Up the Equipment, page 11).

 

The Auto-Vent valve does not vent

Make sure the Auto-Vent valve

 

air when the pot is filled.

is working. Perform the Auto-

 

 

Vent cleaning procedure (see

 

 

Cleaning the Auto-Vent Valve, page 31).

 

The diaphragm valve is

Perform the diaphragm

 

malfunctioning.

flush procedure (see

 

 

Flushing the Diaphragm Valve, page 29).

 

 

If flushing does not solve problem, see

 

 

Repairing the Diaphragm Valve, page 30.

 

There is blockage inside the pot or

Make sure the ball valve is closed, then

 

inside the abrasive hose between

disconnect the cam-lock coupler. Open

 

the pot and the panel.

the abrasive ball valve slightly and make

 

 

sure abrasive is flowing form the abrasive

 

 

hose. If not, follow the shut down

 

 

procedure (see Shutting Down, page 19).

 

 

Thoroughly flush the pot and the media

 

 

hose after draining media and water.

24

334667B

Image 24
Contents Important Safety Instructions EcoQuip Vapor Abrasive Blast SystemModels Related ManualsDust and Debris Hazard Burn Hazard OEM System Guidelines MetricCompressor Size and Hose Length Minimum ID Metric System Component Identification EQ300C and EQ600CDataTrak Controls KeyDataTrak see DataTrak Controls, Pressure Relief Procedure Checklist Before Starting OperationConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting Tips Blasting on Higher SurfacesMetering Valve Settings Grit Size Blast Pressure Abrasive Dose Blast Angle GeneralWood SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment Troubleshooting Problem Cause SolutionSee Cleaning the Auto-Vent Valve, See Repairing the Main Air RegulatorSee Setting Up the Equipment, See Repairing the Diaphragm ValveProcedure see Shutting Down, Intact. See Hose Schematic,Properly. See Hose Schematic, Metering Valve Settings,See Pressure Relief Procedure, Setting Up the Equipment,If flushing does not solve the problem, see Troubleshooting Examples Checking for LeaksPneumatic Blast Control Circuit Repairing the Main Air Regulator Perform Pressure Relief Procedure,Repair Flushing the Diaphragm Valve Repairing the Diaphragm Valve Perform the Pressure Relief Procedure,Cleaning the Auto-Vent Valve Replacing the DataTrak Battery Replace BatteryApproved Batteries Replacing the DataTrak Fuse Replace FuseApproved Fuses DataTrak Part Series Letter Fuse Required Parts EQ300C and EQ600CEQ300C and EQ600C Parts List Pressure POTEnclosure Enclosure Parts List Part Description QtyPressure Pot Parts List Pressure PotRef. Part Description Qty Hose Schematic Vapor Abrasive Blast Systems and Accessories EcoQuip Skid SystemsEcoQuip Trailer Systems Model Series BrakesMobile/Skid Units Trailer UnitsModel Model DescriptionHoses NozzlesModel Description Type Length Blast Control Other Accessories Common Spare PartsDimensions Technical Specifications EQ300SEQ600S Graco Extended Warranty for EcoQuip Components Graco Information