Graco EQ300C manual Refilling the Pot with Abrasive

Page 18

Operation

Refilling the Pot with Abrasive

1.Close the abrasive ball valve.

2.Turn the selector valve to RINSE.

3.Open the dump valve slowly to relieve the water pressure in the pot.

NOTE: Be prepared to capture the water that will be drained from the pot. All disposals must comply with national, state, and local regulations.

4.After all of the pressure in the pot has been relieved, engage the bung pin by compressing the spring and turning the handle 90° to hold the bung in the open position.

5.Add the abrasive (minimum four bags, maximum ten 50 lb (23 kg) bags of high-mass abrasive or eight 50 lb (23 kg) bags of low-mass abrasive) and continue the procedures from Setting Up the Equipment, page 11.

NOTE: More water may need to be drained from the pot to allow additional abrasive to be added.

18

334667B

Image 18
Contents Important Safety Instructions EcoQuip Vapor Abrasive Blast SystemModels Related ManualsDust and Debris Hazard Burn Hazard OEM System Guidelines MetricCompressor Size and Hose Length Minimum ID Metric System Component Identification EQ300C and EQ600CDataTrak Controls KeyDataTrak see DataTrak Controls, Pressure Relief Procedure Checklist Before Starting OperationConnecting the Blast Hose and Air Hose Setting Up the Equipment 10 gal 200-500 lb Ti24824a 0 0 0 8 8 0 0 0 3 Blasting Tips Blasting on Higher SurfacesWood Metering Valve SettingsGrit Size Blast Pressure Abrasive Dose Blast Angle General SteelUsing the Wash Feature Refilling the Pot with Abrasive Shutting Down Operation Winterizing the Equipment See Cleaning the Auto-Vent Valve, TroubleshootingProblem Cause Solution See Repairing the Main Air RegulatorProcedure see Shutting Down, See Setting Up the Equipment,See Repairing the Diaphragm Valve Intact. See Hose Schematic,See Pressure Relief Procedure, Properly. See Hose Schematic,Metering Valve Settings, Setting Up the Equipment,If flushing does not solve the problem, see Troubleshooting Examples Checking for LeaksPneumatic Blast Control Circuit Repairing the Main Air Regulator Perform Pressure Relief Procedure,Repair Flushing the Diaphragm Valve Repairing the Diaphragm Valve Perform the Pressure Relief Procedure,Cleaning the Auto-Vent Valve Replacing the DataTrak Battery Replace BatteryApproved Batteries Replacing the DataTrak Fuse Replace FuseApproved Fuses DataTrak Part Series Letter Fuse Required Parts EQ300C and EQ600CEQ300C and EQ600C Parts List Pressure POTEnclosure Enclosure Parts List Part Description QtyPressure Pot Parts List Pressure PotRef. Part Description Qty Hose Schematic EcoQuip Trailer Systems Vapor Abrasive Blast Systems and AccessoriesEcoQuip Skid Systems Model Series BrakesModel Mobile/Skid UnitsTrailer Units Model DescriptionHoses NozzlesModel Description Type Length Blast Control Other Accessories Common Spare PartsDimensions Technical Specifications EQ300SEQ600S Graco Extended Warranty for EcoQuip Components Graco Information