Kodak i800 Series manual Message Description Feeder self test failed Action

Page 75

Message

Description

Message

Feeder self test failed

Action

The self-test of the paper feeder failed. Perform a controlled power-down

 

sequence on the scanner. If the problem persists, call Service.

 

 

Message

Front image cal unsuccessful

Action

The imaging calibration for the front camera was unsuccessful. Clean the

 

imaging guides and retry calibration. See Chapter 5, Maintenance, “Cleaning the

 

imaging guides” for cleaning procedures.

 

 

Message

Image address field overflow

Action

One of the image address fields has exceeded its maximum configured count.

 

Check to make sure that a level change was not missed or reconfigure the

 

scanner to allow a larger value for the overflowed field.

 

 

Message

Image buffer almost full

Action

The feeder has stopped and the transport is still running because the image buffer

 

is almost full. Processing will resume when the buffer is less full.

 

 

Message

Image buffer full

Action

The image buffer overflowed.

 

One or more documents that passed through the transport were not scanned.

 

Refeed all documents for which images were not obtained.

 

 

Message

Images in buffer

Action

You tried to enable the scanner when images were still in the buffer. Not all

 

images were retrieved. Retrieve the remaining images or clear the buffer. When

 

the buffer is cleared, you may enable the scanner.

 

 

Message

Interlocks are closed

Action

Informational message. All doors are closed.

 

 

Message

Interlocks are open

Action

One of the doors is not closed or an error has not been cleared since the door(s)

 

was last opened. Check to see that all doors are closed and clear the error by

 

pressing the Return arrow (left button) on the Control Panel.

 

 

Message

Invalid IA level

Action

The image address level you tried to enter is not valid. Re-enter a correct image

 

address level. For more information about image addressing, see Kodak

 

publication, Kodak i800 Series Scanners, Image Processing Guide, A-61510.

 

 

Message

IPB needs firmware

Action

There is no firmware in an image processing board. Firmware needs to be

 

installed in all image processing boards before scanning is possible. Call Service.

 

 

Message

Lamps not ready

Action

Calibration and/or scanning was attempted before the lamps were warmed up.

 

See Chapter 3, Operator Control Panel Function’s for calibration guidelines and

 

procedures.

 

 

Message

Lamps ready for scanning

Action

Although lamps have warmed up sufficiently to allow scanning, image quality will

 

be best after the lamps have stabilized after approximately 10 minutes.

 

 

A-61169 July 2003

6-7

Image 75
Contents User’s Guide ElectroMagnetic Compatibility Statements User PrecautionsPeoples Republic of China Class a Japan Class aIntroduction Product description Standard features Speeds Standard configurations Transport speedResolutions Dimension Minimum Maximum Operational ModeScanner specifications Back of scanner Equipment disposal InformationTurning on the scanner To turn on the scanner Using the ScannerJuly July Adjusting the side guides on the input tray Adjusting the output tray Scanning documents Press Start/Resume∙ Press Stop/Pause Continuous and manual feeding Loading long documents in the feederFeeding thick documents Operator Control Panel Functions Scanner Enabling and disablingDisabled scanner functions Navigating through the functions on the control panel menu July Mode Running in count-onlyPress Start/Resume Press Stop/Pause Menu Using the SettingsChanging the alarm VolumeContrast To 4 = lightest, 4 = darkest Changing the displayTermination Changing the ScsiJuly Press Start/Resume Jogging the transport Programmable key assignments Document Printer Document Printer and Patch ReaderJuly July July Improper ink flow Replacing the inkCartridge Locking bar July July Position Setting the printerPatch types Patch ReaderLeading Edge July Cleaning the paper path MaintenanceCleaning the upper transport area Vacuum the area Close the top turn baffle July Transport area Cleaning the verticalCleaning the transport area Lift the roller cover and vacuum the sensors July Cleaning the printer and patch head Cleaning the imaging guides Maintenance and replacement procedures Replacing the feed module Replacing the feed module and feed module tiresModule tires Replacing the feedInstall each new tire by gently stretching it over the core Replacing the separation roller Separation roller and tiresPad Replacing the separationRoller tires Changing the separationReplacing lamps Cleaning the feed module tires and separation roller tiresJuly Position the new lamp in the lamp holder July Customizing the side guides for self- centering feeding July Changing the output tray side guides July Description CAT No Ordering suppliesClearing the document path Front cover accessTop cover access Clearing the document path bi-fold door access July Message Listing Message Error Reset Scanner Action Message Clean imaging guides ActionMessage Clean the S1 sensor Action Message Clean the S2 sensor ActionMessage Image buffer almost full Action Message Description Feeder self test failed ActionMessage Front image cal unsuccessful Action Message Image address field overflow ActionMessage Multi-feed count Action Message Power-on self-test succeeded ActionMessage Description Mechanical cal unsuccessful Action Message Motor self test failed ActionMessage Refeed document set Action Message Settings conflict ActionMessage Description Print head not present Action Message Rear image cal unsuccessful ActionLocation Message Description Unable to enable ActionMessage Unable to execute command Action Document sensorProblem Possible Solutions Problem solving chartProblem Possible Solutions Maintenance Problem Possible Solutions Eastman Kodak Company