Camera unit/Inside the camera
TThis is when the dome cover, inner cover and outer case is removed. How to remove ( A Pg. 17 eMounting on a ceilingf Steps 3. to 5.)
W
Lens section (A Pg. 13)
J
K
L |
M
N
H Power supply/Alarm signal cable (A Pg. 24, 26)
Signal name | Cable color |
|
|
Alarm input 1 | Pink |
|
|
Alarm input 2 | Blue |
|
|
Alarm output 1 | Orange |
|
|
Alarm output 2 | Yellow |
|
|
GND | Brown |
|
|
DC 12 V power supply+ | Red |
|
|
DC 12 V power supply- | Black |
|
|
Note:
●Do not use PoE together with DC 12 V power supply. Simultaneous connection will cause failure or malfunction.
I
(A Pg. 26)
JStrap
This sheet connects the camera unit to the dome cover.
Behind the camera unit
V
UP
T Y
MAC address
S
R X
Q
P
O
K Fastening screw (x3)
This is the screw head of the ceiling mounting bracket Q, which is used to embed the camera in the ceiling.
L [RESET] Reset button
This is a button for rebooting the camera. Press this button and release within 5 seconds to reboot the camera. It takes about 1 minute for the camera to reboot. During startup, [RESET] button is disabled.
Note:
●Pressing the [RESET] button for 5 seconds or longer switches the camera to the service verification mode. Do not press the button for 5 seconds or longer.
M [MONITOR] Monitor terminal (RCA pin) (A Pg. 27)
N Camera unit
O
P
mounting screw
Connect the camera unit N and the outer case C with the
11