Setup
LAN Cable Connection
Connect the camera to a hub or computer using a LAN cable.
When connecting to a hub
Make use of a straight cable.
When connecting to a computer
Make use of a Cross Over cable.
LAN cable
Alarm Input/Output Cable Connection
Connect the alarm input/output cables with external devices such as a sensor, buzzer, etc.
Signal name  | Cable color  | 
  | 
  | 
Alarm input 1  | Pink  | 
  | 
  | 
Alarm input 2  | Blue  | 
  | 
  | 
Alarm output 1  | Orange  | 
  | 
  | 
Alarm output 2  | Yellow  | 
  | 
  | 
GND  | Brown  | 
  | 
  | 
Cable to use
●Length of 50 m or shorter
●UL1007, UL1015 or equivalent products
●AWG#22 - AWG#18 or equivalent products
 Alarm input/output cables
Solder or crimp
Wind the  | 
  | |
waterproof  | Insulation tape  | |
tape.  | ||
  | 
Note:
●Cross cables cannot be used with some computer models. When connecting VN- C215V4U directly to a computer, make sure to check the computer’s LAN specifications in advance.
Memo:
●Make use of a Category 5 (or higher) cable in the case of 
Note:
●Noises from an external source may cause malfunctions even when the cable used is shorter than 50 m. In this case, use a shielded cable or move the cable away from the noise source.