Bosch Appliances 5000 IP installation manual Multicast, Rtsp port, UPnP, TCP Metadata

Page 110

110 en Advanced Mode

DINION capture 5000 IP

 

 

RTSP port

If necessary, select a different port from the list for the exchange of the RTSP data. The standard RTSP port is 554. Select Off to deactivate the RTSP function.

UPnP

Select On to activate UPnP communication. Select Off to deactivate it.

When UPnP is activated the camera reacts to requests from the network and is registered automatically as a new network device on the inquiring computers.

Note:

To use the UPnP function on a computer with Windows XP or Windows Vista, the Universal Plug and Play Device Host and the SSDP Discovery services must be activated.

This function should not be used in large installations due to the large number of registration notifications.

TCP Metadata

The device can receive data from an external TCP sender, for example an ATM or POS device, and store it as metadata. Select the port for TCP communication. Select Off to deactivate the function. Enter a valid Sender IP address.

8.8.3Multicast

In addition to a one-to-one connection between a camera and a single receiver (unicast), the camera can enable multiple receivers to receive the video signal simultaneously. This is either done by duplicating the data stream in the device and then distributing it to multiple receivers (multi-unicast), or by distributing an individual data stream in the network itself to multiple receivers in a defined group (multicast). Enter a dedicated multicast address and port for each stream. Then switch between the streams by clicking the associated tabs. The prerequisite for multicast operation is a multicast-capable network that uses the UDP and IGMP protocols. Other group membership protocols are not supported. The TCP protocol does not support multicast connections.

1.0 2012.01

Installation Manual

Bosch Security Systems, Inc.

Image 110
Contents Dinion capture 5000 IP Page Table of Contents Operation via the browser Basic ModeAdvanced Mode ALC Dimensional Drawings 116 Safety Safety precautionsImportant safety instructions Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP Important notices Risk GroupCoax grounding Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP Informations FCC et Ices FCC & Ices complianceFCC & Ices Information En Safety Dinion capture 5000 IP Copyright Bosch noticesVideo loss TrademarksQuantity Description Parts ListDescription Ranges based on capturing Installing the Dinion captureDetermining the Range Field of View at Optimal Capture DistanceRange Distance Determining the AngleModel Capture Optimal Mounting the Dinion capture En Installing the Dinion capture Dinion capture 5000 IP Dinion capture 5000 IP Installing the Dinion capture en Preparing the Wiring Video Connection for Installation Power Input ConnectionsEthernet and Power Connections Making the Connections Connecting to a Coax Cable Using a microSD Card To insert a microSD cardResetting the Dinion capture 5000 IP Automatic Mode Switching Mode Details To setup Automatic Mode SwitchingTo disable Automatic Mode Switching 1 Alarm input, page 103, for more informationMenu Navigation Keys ConfigurationInstall Menu Mode FullSun ModePre-Defined Modes Lens Wizard submenu Selection DescriptionDefault submenu Network submenuBrowser connection System requirementsProtected network Password protection in cameraEstablishing the connection Connecting to a hardware decoder Alarm connectionConnection established LivepageSettings Processor load Operation via the browserLivepage Image selection Display StampingDigital I/O System Log / Event LogRunning recording program Saving snapshotsRecording video sequences Audio communication Selecting Recordings RecordingsControlling playback Export to FTPSlide control BookmarksSaving changes Basic ModeBasic Mode menu tree Password Device AccessPassword Camera nameDevice date, time and zone Confirm passwordDate/Time Time server IP addressIP address Click Set and RebootNetwork Subnet maskSystem Overview EncoderRecording Storage mediumAdvanced Mode Advanced Mode menu treeDinion capture 5000 IP Advanced Mode en Camera ID GeneralIdentification Camera namePassword Device date / Device time Date/TimeDate format Device time zoneDisplay Stamping Camera name stampingTime stamping Alarm mode stampingAlarm message Display millisecondsWeb Interface AppearanceLivepage Functions Logging Pre-defined modes CameraMode Restore Mode Defaults Mode IDCopy mode to Peak average 2 ALCALC level SpeedShutter Default shutter / Fixed shutterShutter/AGC Actual shutterMaximum gain / Fixed gain EnhanceGain Actual gainDynamic noise reduction Auto blackSharpness level Peak white invertInstallation Manual Target bit rate Profile ConfigurationProfile name Maximum bit rate4CIF/D1 Video resolutionExpert Settings GOP structureDefault 264 BP+ bit-rate-limited MP SD Select H.264 SettingsEncoder Streams 264 BP+ bit-rate MP SD LimitedJpeg stream Privacy MasksAudio En Advanced Mode Dinion capture 5000 IP Installer Menu Recording Storage Management Formatting Storage Media Deactivating Storage Media Recording includes Stream profile settingsRecording Profiles Standard recordingAlarm recording Retention TimeHolidays Recording SchedulerWeekdays Activate recording Recording StatusProfile names Recording statusAlarm Alarm ConnectionsStream Select 10 in the Number of destination IP address list boxVideo transmission Remote portAuto-connect DecoderSSL encryption AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sSensitivity Analysis typeMotion detector Selecting the area Minimum object sizeDebounce time 1 s Global change slider Trigger delay sTamper detection Global changeScene too noisy Scene too brightScene too dark Reference checkAppearing edges VCA configuration Scheduled Deleting HolidaysDinion capture 5000 IP Advanced Mode en Trigger VCA configuration Event triggeredDelay s Trigger activeSignal Ranges Audio AlarmAudio alarm NameAlarm E-Mail Test e-mail Destination addressSender name Alarm Task Editor Relay Alarm inputInterfaces Trigger relay Network Access Automatic IP assignmentHttp browser port DNS server addressDetails Video transmission Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportForce registration now Host nameUser name StatusSnmp host address / 2. Snmp host address AuthenticationAdvanced Snmp trapsUPnP MulticastRtsp port TCP MetadataPort EnableMulticast Address StreamingFTP Posting Encryption ServiceMaintenance FirmwareConfiguration System Overview Maintenance logLicenses SSL certificateDimensional Drawings Dinion capturePage Bosch Security Systems, Inc