Bosch Appliances 5000 IP installation manual Recording Scheduler, Weekdays, Holidays

Page 84

84 en Advanced Mode

DINION capture 5000 IP

 

 

8.5.4Recording Scheduler

The recording scheduler allows you to link the created recording profiles to the days and times at which the camera's images are to be recorded in the event of an alarm. Schedules can be defined for weekdays and for holidays.

Weekdays

Assign as many time periods (in 15-minute intervals) as needed for any day of the week. Move the mouse cursor over the table — the time is displayed.

1.Click the profile to be assigned in the Time periods box.

2.Click a field in the table and, while holding down the left mouse button, drag the cursor across all of the fields to be assigned to the selected profile.

3.Use the right mouse button to deselect any of the intervals.

4.Click Select All to select all of the intervals to be assigned to the selected profile.

5.Click Clear All to deselect all of the intervals.

6.When finished, click Set to save the settings to the device.

Holidays

Define holidays whose settings will override the settings for the normal weekly schedule.

1.Click the Holidays tab. Days that have already been defined are shown in the table.

2.Click Add. A new window opens.

3.Select the desired date from the calendar. Drag the mouse to select a range of dates. These are handled as a single entry in the table.

4.Click OK to accept the selection(s). The window closes.

5.Assign the defined holidays to the recording profile as

described above.

Delete user-defined holidays at any time.

1.Click Delete in the Holidays tab. A new window opens.

2.Click the date to be deleted.

3.Click OK. The selection is removed from the table and the window is closed.

4.Repeat for any other dates to be deleted.

1.0 2012.01

Installation Manual

Bosch Security Systems, Inc.

Image 84
Contents Dinion capture 5000 IP Page Table of Contents Basic Mode Advanced ModeOperation via the browser ALC Dimensional Drawings 116 Safety Safety precautionsImportant safety instructions Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP Important notices Risk GroupCoax grounding Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP FCC & Ices compliance FCC & Ices InformationInformations FCC et Ices En Safety Dinion capture 5000 IP Bosch notices Video lossCopyright TrademarksParts List DescriptionQuantity Description Installing the Dinion capture Determining the RangeRanges based on capturing Field of View at Optimal Capture DistanceDetermining the Angle Model Capture OptimalRange Distance Mounting the Dinion capture En Installing the Dinion capture Dinion capture 5000 IP Dinion capture 5000 IP Installing the Dinion capture en Preparing the Wiring Power Input Connections Ethernet and Power ConnectionsVideo Connection for Installation Making the Connections Connecting to a Coax Cable Using a microSD Card To insert a microSD cardResetting the Dinion capture 5000 IP Automatic Mode Switching Mode Details To setup Automatic Mode SwitchingTo disable Automatic Mode Switching 1 Alarm input, page 103, for more informationConfiguration Install MenuMenu Navigation Keys FullSun Mode Pre-Defined ModesMode Lens Wizard submenu Selection DescriptionDefault submenu Network submenuBrowser connection System requirementsPassword protection in camera Establishing the connectionProtected network Connecting to a hardware decoder Alarm connectionConnection established LivepageSettings Operation via the browser LivepageProcessor load Image selection Display StampingDigital I/O System Log / Event LogSaving snapshots Recording video sequencesRunning recording program Audio communication Recordings Controlling playbackSelecting Recordings Export to FTPSlide control BookmarksBasic Mode Basic Mode menu treeSaving changes Device Access PasswordPassword Camera nameConfirm password Date/TimeDevice date, time and zone Time server IP addressClick Set and Reboot NetworkIP address Subnet maskEncoder RecordingSystem Overview Storage mediumAdvanced Mode Advanced Mode menu treeDinion capture 5000 IP Advanced Mode en General IdentificationCamera ID Camera namePassword Date/Time Date formatDevice date / Device time Device time zoneDisplay Stamping Camera name stampingAlarm mode stamping Alarm messageTime stamping Display millisecondsWeb Interface AppearanceLivepage Functions Logging Camera ModePre-defined modes Mode ID Copy mode toRestore Mode Defaults 2 ALC ALC levelPeak average SpeedDefault shutter / Fixed shutter Shutter/AGCShutter Actual shutterEnhance GainMaximum gain / Fixed gain Actual gainAuto black Sharpness levelDynamic noise reduction Peak white invertInstallation Manual Profile Configuration Profile nameTarget bit rate Maximum bit rateVideo resolution Expert Settings4CIF/D1 GOP structureDefault Select H.264 Settings Encoder Streams264 BP+ bit-rate-limited MP SD 264 BP+ bit-rate MP SD LimitedPrivacy Masks AudioJpeg stream En Advanced Mode Dinion capture 5000 IP Installer Menu Recording Storage Management Formatting Storage Media Deactivating Storage Media Stream profile settings Recording ProfilesRecording includes Standard recordingAlarm recording Retention TimeRecording Scheduler WeekdaysHolidays Recording Status Profile namesActivate recording Recording statusAlarm Alarm ConnectionsSelect 10 in the Number of destination IP address list box Video transmissionStream Remote portDecoder SSL encryptionAuto-connect AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sAnalysis type Motion detectorSensitivity Minimum object size Debounce time 1 sSelecting the area Trigger delay s Tamper detectionGlobal change slider Global changeScene too bright Scene too darkScene too noisy Reference checkAppearing edges VCA configuration Scheduled Deleting HolidaysDinion capture 5000 IP Advanced Mode en VCA configuration Event triggered Delay sTrigger Trigger activeAudio Alarm Audio alarmSignal Ranges NameAlarm E-Mail Destination address Sender nameTest e-mail Alarm Task Editor Alarm input InterfacesRelay Trigger relay Network Access Automatic IP assignmentDNS server address Details Video transmissionHttp browser port Https browser portInterface mode ETH Enable DynDNSRCP+ port Telnet supportHost name User nameForce registration now StatusAuthentication AdvancedSnmp host address / 2. Snmp host address Snmp trapsMulticast Rtsp portUPnP TCP MetadataEnable Multicast AddressPort StreamingFTP Posting Service MaintenanceEncryption FirmwareConfiguration Maintenance log LicensesSystem Overview SSL certificateDimensional Drawings Dinion capturePage Bosch Security Systems, Inc