44 en Operation via the browser | DINION capture 5000 IP |
|
|
Motion flag set on media item
Discovery of storage not completed.
If the information about recorded video is not cached, a discovery procedure is started to find all recorded video. During this time, the discovery symbol is shown. While discovery is executed, gaps might be shown in places which the discovery has not yet reached. The gap will be automatically replaced by the true video, as soon as the correct information is available.
6.1.3Digital I/O
Depending on the configuration of the unit, the alarm input and the relay output are displayed next to the camera image. The alarm symbol is for information and indicates the input status of the alarm input: Active 1 = Symbol lights, Active 0 = Symbol not lit. The relay on the camera allows the operation of a device (for example, a light or a door opener).
NOTICE!
Alarm 1 is reserved for Automatic Mode Switching, when Mode 2 (FullSun) is active the symbol will be lit. Automatic Mode Switching must be activated to operate, refer to
Section 3.9 Automatic Mode Switching, page 30.
–To operate, click the relay symbol. The symbol is red when the relay is activated.
6.1.4System Log / Event Log
The System Log field contains information about the operating status of the camera and the connection. These messages can be saved automatically in a file. Events such as the triggering or end of alarms are shown in the Event Log field. These messages can be saved automatically in a file. To delete the entries, click the icon in the top
1.0 2012.01 | Installation Manual | Bosch Security Systems, Inc. |