Bosch Appliances 5000 IP Encoder Streams, Select H.264 Settings, 264 BP+ bit-rate-limited MP SD

Page 74

74 en Advanced Mode

DINION capture 5000 IP

 

 

8.4.6Encoder Streams

Select H.264 Settings

1.Select the codec algorithm for streams 1 and 2. The following algorithms are available

H.264 BP+ bit-rate-limited

H.264 MP SD

2.Select the default profile for streams 1 and 2 from the eight profiles that have been defined.

The algorithm properties have the following settings:

 

H.264 BP+ bit-rate-

H.264 MP SD

 

limited

 

 

 

 

CABAC

off

on

 

 

 

CAVLC

on

off

 

 

 

GOP structure

IP

IP

 

 

 

I-frame distance

15

30

 

 

 

Deblocking filter

on

on

 

 

 

Bit rate

limited to 1.2 Mbps

 

 

 

 

Recommended for

Hardware

Software decoders,

 

decoders,

PTZ and rapid

 

DVR 700 Series

image movements

 

 

 

Preview >>

Previews of streams 1 and 2 can be shown.

1.Click Preview >> to display a preview of the video for streams 1 and 2. The current profile is shown above the preview.

2.Click 1:1 Live View below a preview to open a viewing window for that stream. Various additional items of information are shown across the top of the window.

3.Click Preview << to close the preview displays.

1.0 2012.01

Installation Manual

Bosch Security Systems, Inc.

Image 74
Contents Dinion capture 5000 IP Page Table of Contents Operation via the browser Basic ModeAdvanced Mode ALC Dimensional Drawings 116 Safety Safety precautionsImportant safety instructions Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP Important notices Risk GroupCoax grounding Dinion capture 5000 IP Safety en En Safety Dinion capture 5000 IP Informations FCC et Ices FCC & Ices complianceFCC & Ices Information En Safety Dinion capture 5000 IP Copyright Bosch noticesVideo loss TrademarksQuantity Description Parts ListDescription Ranges based on capturing Installing the Dinion captureDetermining the Range Field of View at Optimal Capture DistanceRange Distance Determining the AngleModel Capture Optimal Mounting the Dinion capture En Installing the Dinion capture Dinion capture 5000 IP Dinion capture 5000 IP Installing the Dinion capture en Preparing the Wiring Video Connection for Installation Power Input ConnectionsEthernet and Power Connections Making the Connections Connecting to a Coax Cable Using a microSD Card To insert a microSD cardResetting the Dinion capture 5000 IP Automatic Mode Switching Mode Details To setup Automatic Mode SwitchingTo disable Automatic Mode Switching 1 Alarm input, page 103, for more informationMenu Navigation Keys ConfigurationInstall Menu Mode FullSun ModePre-Defined Modes Lens Wizard submenu Selection DescriptionDefault submenu Network submenuBrowser connection System requirementsProtected network Password protection in cameraEstablishing the connection Connecting to a hardware decoder Alarm connectionConnection established LivepageSettings Processor load Operation via the browserLivepage Image selection Display StampingDigital I/O System Log / Event LogRunning recording program Saving snapshotsRecording video sequences Audio communication Selecting Recordings RecordingsControlling playback Export to FTPSlide control BookmarksSaving changes Basic ModeBasic Mode menu tree Password Device AccessPassword Camera nameDevice date, time and zone Confirm passwordDate/Time Time server IP addressIP address Click Set and RebootNetwork Subnet maskSystem Overview EncoderRecording Storage mediumAdvanced Mode Advanced Mode menu treeDinion capture 5000 IP Advanced Mode en Camera ID GeneralIdentification Camera namePassword Device date / Device time Date/TimeDate format Device time zoneDisplay Stamping Camera name stampingTime stamping Alarm mode stampingAlarm message Display millisecondsWeb Interface AppearanceLivepage Functions Logging Pre-defined modes CameraMode Restore Mode Defaults Mode IDCopy mode to Peak average 2 ALCALC level SpeedShutter Default shutter / Fixed shutterShutter/AGC Actual shutterMaximum gain / Fixed gain EnhanceGain Actual gainDynamic noise reduction Auto blackSharpness level Peak white invertInstallation Manual Target bit rate Profile ConfigurationProfile name Maximum bit rate4CIF/D1 Video resolutionExpert Settings GOP structureDefault 264 BP+ bit-rate-limited MP SD Select H.264 SettingsEncoder Streams 264 BP+ bit-rate MP SD LimitedJpeg stream Privacy MasksAudio En Advanced Mode Dinion capture 5000 IP Installer Menu Recording Storage Management Formatting Storage Media Deactivating Storage Media Recording includes Stream profile settingsRecording Profiles Standard recordingAlarm recording Retention TimeHolidays Recording SchedulerWeekdays Activate recording Recording StatusProfile names Recording statusAlarm Alarm ConnectionsStream Select 10 in the Number of destination IP address list boxVideo transmission Remote portAuto-connect DecoderSSL encryption AudioVideo Content Analyses VCA VCA configuration- Profiles Aggregation time sSensitivity Analysis typeMotion detector Selecting the area Minimum object sizeDebounce time 1 s Global change slider Trigger delay sTamper detection Global changeScene too noisy Scene too brightScene too dark Reference checkAppearing edges VCA configuration Scheduled Deleting HolidaysDinion capture 5000 IP Advanced Mode en Trigger VCA configuration Event triggeredDelay s Trigger activeSignal Ranges Audio AlarmAudio alarm NameAlarm E-Mail Test e-mail Destination addressSender name Alarm Task Editor Relay Alarm inputInterfaces Trigger relay Network Access Automatic IP assignmentHttp browser port DNS server addressDetails Video transmission Https browser portRCP+ port Interface mode ETHEnable DynDNS Telnet supportForce registration now Host nameUser name StatusSnmp host address / 2. Snmp host address AuthenticationAdvanced Snmp trapsUPnP MulticastRtsp port TCP MetadataPort EnableMulticast Address StreamingFTP Posting Encryption ServiceMaintenance FirmwareConfiguration System Overview Maintenance logLicenses SSL certificateDimensional Drawings Dinion capturePage Bosch Security Systems, Inc