12 en Safety | DINION capture 5000 IP |
|
|
The Exposure Hazard Value for the product (ratio of the Exposure level to the Exposure limit) is up to 1.8 at a test distance of 200 mm or 8 inches. The Hazard Distance (distance beyond which the product falls into the exempt/safe group) is at most 350 mm or 14 inches. Note that typical operating distances for license plate capture (3.8 m or 12.5 feet and greater) are much greater than the Hazard Distance.
When servicing the unit, physically disconnect the power supply to avoid possible IR exposure to the eyes. If physical disconnection is not possible, use appropriate shielding to block the LED panel or use eye protection with a transmission of 50% or less at a wavelength of 850 nm.
Coax grounding:
–Ground the cable system if connecting an outside cable system to the unit.
–Follow proper safety precautions such as grounding for
any outdoor device connected to this unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regarding proper grounding of the mount and supporting structure, grounding of the coax to a discharge unit, size of grounding conductors, location of discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.
Disposal - Your Bosch product was developed and manufactured with
EC
Electronic Surveillance - This device is intended for use in public areas only. U.S. federal law strictly prohibits surreptitious recording of oral communications.
1.0 2012.01 | Installation Manual | Bosch Security Systems, Inc. |