38 en Browser connection | DINION capture 5000 IP |
|
|
5.2Establishing the connection
The DINION capture 5000 IP must be assigned a valid IP address to operate on your network. The default address pre- set at the factory is 192.168.0.1
1.Start the Web browser.
2.Enter the IP address of the camera as the URL.
Note:
If the connection is not established, the maximum number of possible connections may already have been reached. Depending on the device and network configuration, up to 25 web browsers, or 50 VIDOS or Bosch VMS connections are supported.
5.2.1Password protection in camera
A camera offers the option of limiting access across various authorization levels. If the camera is
1.Enter the user name and the associated password in the appropriate fields.
2.Click OK. If the password is correct, the desired page is displayed.
5.3Protected network
If a Radius server is used for network access control (802.1x authentication), the camera must be configured first. To configure the camera for a Radius network, connect it directly to a PC via a crossed network cable and configure the two parameters, Identity and Password. Only after these have been configured can communication with the camera via the network occur.
1.0 2012.01 | Installation Manual | Bosch Security Systems, Inc. |