Samsung SCC-C6475(P) manual Initial Setting, Setting RS-422A/RS-485 termination, Baud Rate Setting

Page 9

INITIAL SETTING

CAMERA ADDRESS SETUP

Use SW701, SW702, or 703 for Camera Address setup. You may allocate up to 255 addresses by using SW701 to set the 3rd digit, SW702 the 2nd digit, and SW703 the 1st digit.

EX) In case of Camera Address 1, see the following figure for setup.

SW701SW702SW703

Setting communication Protocol

Use number 1~4 PIN of SW704 to set communication Protocol.

Setting RS-422A/RS-485 termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

As it is shown in the structure map, when Controller and RS-422A/RS-

 

485 is connected it should be terminated according to the Cable feature

 

E

of impedance on the each end of the transmitting line to transfer the

 

 

signals in long distance by controlling the reflection of the signals to the

 

lowest.

 

 

 

 

 

 

 

 

 

 

 

 

Division

n < 32

 

 

 

 

 

 

 

 

PIN

PIN1

PIN2

PIN3

PIN4

Comp

A

OFF

OFF

OFF

OFF

B

ON

OFF

OFF

OFF

C

OFF

ON

OFF

OFF

D

ON

ON

OFF

OFF

E

OFF

OFF

ON

OFF

F

ON

OFF

ON

OFF

G

OFF

ON

ON

OFF

H

ON

ON

ON

OFF

I

OFF

OFF

OFF

ON

J

ON

OFF

OFF

ON

K

OFF

ON

OFF

ON

L

ON

ON

OFF

ON

M

OFF

OFF

ON

ON

A : SAMSUNG HALF

B : SAMSUNG FULL

SEE INSTRUCTION MANUAL

ON 1 2 3 4 5 6 7 8

SW704

(x100) (x10) (x1)

SW701 SW702 SW703

Termination

SW1-ON

<RS-485 Half Duplex Organization>

Termination: using numbers 1 and 2 PIN, turn to ON and it will be terminated.

n < 32

N

ON

OFF

ON

ON

O

OFF

ON

ON

ON

P

ON

ON

ON

ON

(BOTTOM VIEW)

Division

Division SW1-ON SW2-ON

Baud Rate Setting

Use PIN 5 and 6 of SW704.

 

1

2

3

4

 

5

6

7

8

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 704

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAUD RATE

 

 

 

 

PIN 5

PIN 6

 

 

4800 BPS

 

 

 

 

 

 

ON

ON

 

 

9600 BPS

 

 

 

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

19200 BPS

 

 

 

 

 

 

ON

OFF

 

 

38400 BPS

 

 

 

 

 

 

OFF

OFF

1-11

<RS-422A/RS-485 Full Duplex Organization>

1-12

Image 9
Contents SCC C6475P Important Safety Instructions FCC Statement Before Usage Table of contents CC-C6475 P Overvi ew ChapterLocations of Control SCC-C6475P IntroductionSCC-C6475P Adapter Board Adapter ConnectionSetting RS-422A/RS-485 termination Initial SettingSetting communication Protocol Baud Rate SettingFactory Default CC- C6475P Installatio nBefore Installing Wall Mount Adaptor SADT-100WM Ceiling Mount Bracket SBR-100DCMOutdoor Housing SHG-220 Indoor Housing SHG-120Ceiling Mount Adaptor SADT-100CM Pole Mount Adaptor SADT-100PMMatch Installing the CameraNetwork Manual Overview Case of using xDSL/Cable Internet network and IP routerPage Case of connecting more than 2 cameras to one IP router Http PortExample http//192.168.1.20181 Case of connecting more than 2 cameras to an IP router Case of using the LAN and IP router Example No.1 SCC-C6475P IP Subnet Mask Gateway Page RJ-45 Cross Lan Cable will be enclosed with products Example IP Subnet mask Gateway Page Case of connecting the camera in the intranet LAN Setting the IPTitle bar and the upper menu LogViewer Screen Logo and Video FormatChoice of camera and channel Screencapture/record/play Screen Size/Alarm/Banner window displayImage screen adjustment Setting the basic functionVideo Page User Preset CameraLanguage Status Setting the systemLog IP FilterReset Software UpdateLayout ParameterOverlay Image Overlay Text View Html Code Screen LookAlarm Transfer SetupAlarm Setup Port Alarm Priority SETNetwork NetworkIP Notification Network Terms Definition Setup Menu Overvie wExit QUIT/SAVE Structure of the Setup MenuCamera SET Menu SyncCamera ID Motion DET COLOR/BWVideo SET Menu AGC ShutterMotion AGC GainDIS White BALFocus Mode PresetSpecial FocusZone SET Blank ALL Above Blank ALL below SET Zone AreaPryvacy Zone MAP Zone DIR SET SET ZoomReverse Zone AreaAuto SET Endless DirectionSpeed PatternAlarm SET Other SET System Info Short KeysSpecifications Installation of IP routerLogin Connecting the InternetSetting the IP sharing setting Example Linksys model WRT54G Set the Time zone Verify the Connection statePort Forwarding Be sure to read this Setting the internet connection Setting the IP router Example Netgear model RP614v2 AccessVerify the connection status Run Wizard Setting IP router Example D-Link model DI-624+First screen Password for RouterTime zone Cable ModemWireless LAN EncryptionRestart Port Forwarding Be sure to read Checking the ConnectionProduct specifications