Trek 11i, 9i To install the sensor, Sensor can be rotated around the fork about 45 degrees, 0mm

Page 11

Attaching the sensors

The magnet must pass across the line on the sensor (Figure 9).

These instructions are written for the front wheel, but apply equally to installing the magnet and cadence sensor which go on the left crank and the frame’s chainstay (Figure 10).

To install the sensor

1.Align the sensor with the magnet.

2.Orient the sensor so that the clearance between the sensor and the magnet is between 1 to 3mm.

The sensor can be rotated around the fork about 45 degrees.

If needed, the sensor and magnet can be moved up or down the spoke and fork to change the amount of clearance.

3.Attach the sensor with nylon ties, but do not fully tighten.

4.With the computer in the computer base, check the alignment of the sensor

Installation

1.0-

3.0mm

Figure 9- Magnet alignment and clearance

Figure 10- Magnet placed on crankarm, aligned with sensor on chainstay

Image 11
Contents Copyright Trek Bicycle Corporation 2006 All rights reserved Trek Incite 9iContents Watch the road when riding Safety and general guidelinesFunction Explanation FunctionsCAD Mount InstallationStem mount Handlebar Speed sensor 31.8mm bars large clamp 25.4mm and 26.0mm small clamp To install the computer on handlebarMake sure the com- puter cannot be bounced off To install the computer on the stemPlacing the magnet To install the wheel magnetTo attach the computer wire Attaching the computer wire0mm To install the sensorSensor can be rotated around the fork about 45 degrees Tighten the nylon ties and trim the excess length Figure Easy setup ReSet Mode Using the buttonsTo set the units SetComputer returns to the start screen Temperature icon displayTo set the odometer MH and KMH interchange on the screenWheel size changes To set wheel sizeWheel Select icon appears on the screen Wheel size appearsTo select the wheel for use Cycle Mode to TRPHour changes To set Clock12 or 24 flashes 24 interchange on the screenTo ReStart set the Trip data to zero Max setting ReStarts at ‘0’Removing the computer from the computer base Changing modeUsing the computer in wet weather Additional informationTroubleshooting To replace the battery Replacing the batteryBe careful to avoid losing the rubber O-ring seal ‘cross’ on the bat- tery points up Replacing the BatteryTo set the computer Setting custom wheel sizeSelecting the custom value 4-digit number Left-hand digit flashes Measuring rollout for wheel size To measure rollout for wheel sizeThis warranty does not cover Limited WarrantyThis warranty covers