Precor 5.21 manual Troubleshooting Heart Rate Program

Page 35

Troubleshooting Heart Rate Program

Table 2 may help you understand and troubleshoot erratic heart rate readings.

Important: A heart rate can only be detected when the EFX is turned On and you hold on to both touch-sensitive grips.

To conduct electrical impulses from a user’s heart, both touch-sensitive grips must be grasped firmly for five to ten seconds. Usually, the concentration of salts in a person’s perspiration provides enough conductivity to transmit a signal to the receiver in the display console. However, because of body chemistry or erratic heartbeats, some people cannot use the heart rate feature.

Table 2. Erratic heart rate readings

What appears

 

 

on the display

Cause

What to Do

 

 

 

Nothing

The heart rate

To receive Customer

 

receiver is not

Support, refer to

 

installed or it has

Obtaining Service.

 

been disconnected.

 

 

 

 

Hr

No signal is being

Use both hands and

 

detected, or the

make sure your hands

 

transmission requires

are moist, not dry.

 

more time to

 

 

establish a heart rate.

 

 

 

 

Pulsing HEART

The heart icon blinks

If the heart icon is

 

when a heart beat is

pulsating, it indicates

 

detected.

that the heart rate

 

 

equipment is working

 

 

properly.

 

 

 

Owner’s Manual: Advanced Programming and Troubleshooting

34

Image 35
Contents EFX Page Important Safety Instructions Important Safety Instructions Units Designated for U.S. Markets Safety ApprovalGrounding Instructions Federal Communications Commission, Part Safety Approvals for Cardiovascular EquipmentRegulatory Notices for Cardiovascular Exercise Equipment Radio Frequency Interference RFICanadian Department of Communications European ApplicationsProduct Recycling and Disposal Obtaining Service Table of Contents Locking Pin EFX FeaturesLocation Using the Stationary HandrailTurning the Unit On and Off Using the Touch-Sensitive Grips Heart Rate FeaturesImportant Safety Instructions To test your current heartrate Exercising to Your Target Heart RateUsing SmartRate 130 888.8 888.8 Display Console130 888.8 888.8 Using the Upper Display130 888.8 888.8 Using the Center DisplayPrograms Key Using the Lower DisplayQuick Lower KeypadEquipment Break-in Notice Workout OptionsAdjusting the Ramp Choosing Quickstart Cooling Down After a Workout Selecting a ProgramEnding a Workout Pausing During a Workout or the Cool-Down PeriodChoosing a Program ProgramsManual Program Program TipsFat Burner Program Weight Loss ProgramInterval Program CrossTrainer ProgramGluteals Program Hill Climb ProgramHeart Rate Program Heart Rate Program Tips Advanced Programming Tips Advanced Programming and TroubleshootingSelecting a U.S. Standard or Metric Display Viewing Other SettingsTroubleshooting Error Codes Viewing the Error LogTroubleshooting Heart Rate Program Inspect the EFX before use MaintenanceCleaning the Equipment Long-Term StorageLimited Warranty Precor Residential Equipment Limited WarrantyThis limited warranty shall not apply to Exclusion of Consequential and Incidental Damages Page Page Tell US about Your NEW Precor Product Thank You and Welcome to Precor EFX5.21/EFX5.23 Elliptical Fitness CrossTrainersTM Product SpecificationsPage Locking Pin on Roller Arm QuickstartChoosing a Program Assembly Guide Page Required Tools Additional Fasteners for EFX5.23 only Quantity Fasteners QuantityAssembly Steps EFX5.21/ 5.23 Elliptical Fitness CrossTrainer Assembly Guide EFX5.21/ 5.23 Elliptical Fitness CrossTrainer Assembly Guide EFX5.21/ 5.23 Elliptical Fitness CrossTrainer Assembly Guide You cannot be standing on the equipment or the foot pedals EFX5.21/ 5.23 Elliptical Fitness CrossTrainer Assembly Guide Page Precor Incorporated