LocationRequirements
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
■A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See “Venting Requirements.”
■A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”
■A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.
■A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. If slope is greater than 1" (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.
■For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need an additional 6" (15.24 cm).
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
NOTE: No other
Installation clearances
■The location must be large enough to fully open the dryer door.
■Additional spacing should be considered for ease of installation and servicing.
■Additional clearances might be required for wall, door and floor moldings.
■Additional spacing of 1" (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.
■Companion appliance spacing should also be considered.
Dryer Dimensions
51½" (130.81 cm)
38"
(96.52 cm)
*31½"
(80 cm)
27"
(68.6 cm)
*Most installations require a minimum 5½" (14 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Minimum installation spacing for custom undercounter installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
0" (0 cm)
38" min. (96.52 cm)
0" |
| 27" |
| 0" |
(0 cm) | (68.6 cm) | (0 cm) |
Minimum installation spacing for recessed or closet installation, with or without a pedestal
■The dimensions shown are for the minimum spacing allowed.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Closet installation - Dryer only
|
|
|
|
| 3" |
| 14" max. |
|
| (7.6 cm) | |
| (35.6 cm) | 48 in.2 |
|
| |
|
|
| (310 cm2) |
| |
| 18" min. |
|
|
| |
| (45.72 cm) |
|
|
| |
|
|
| 24 in.2 | 2) |
|
|
|
| (155 cm | 3" | |
|
|
|
|
| |
|
|
|
|
| (7.6 cm) |
0" | 31½" | 0" |
|
|
|
(0 cm) (80 cm) | (0 cm) |
|
|
| |
| A |
|
|
| B |
A. Side view - closet or confined area
B. Closet door with vents
6