Whirlpool 8528095 REV A Installation Requirements, Tools and Parts, Location Requirements

Page 3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Flat-blade screwdriver

Phillips screwdriver

Adjustable wrench that opens to 2.5 cm (1")

Hex-head socket wrench

Level

1/4" socket wrench or 1/4" nut driver

Utility knife

Vent clamps

Pipe-joint compound resistant to LP gas

Caulk gun and caulk (for installing new exhaust vent)

Tin snips

Parts supplied

Remove parts bag from dryer drum. Check that all parts were included.

4 leveling legs

Location Requirements

WARNING

Recessed Area and Closet Installation Instructions

This dryer may be installed in a recessed area or closet. For recessed area and closet installations, minimum clearances can be found on the serial tag on the dryer.

The installation spacing is in centimeters (inches) and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.

If closet door is installed, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.

The dryer must be exhausted outdoors.

No other fuel-burning appliance may be installed in the same closet as the dryer.

Minimum Installation Clearances

 

35.6 cm

 

(14") max.

45.7 cm

Closet

(18")*

door

 

10.2 cm

2.5 cm (1")

(4")

2.5 cm (1")

 

2.5 cm (1")

Recessed front view

Closet side view

Additional clearances for wall, door and floor moldings may be required or if external exhaust elbow is used.

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 46 cm (18 inches) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

IMPORTANT: Observe all governing codes and ordinances.

310cm2

(48"2)

Front

View

155cm2

(24"2)

7.6 cm (3")

closet

door

7.6 cm (3")

Check code requirements: Some codes limit or do not permit installation of clothes dryers in garages, closets, or sleeping quarters. Contact your local building inspector.

Make sure that lower edges of the cabinet, plus the back and bottom sides of the dryer, are free of obstructions to permit adequate clearance of air openings for combustion air. See “Recessed Area and Closet Installation Instructions” for minimum spacing requirements.

NOTE: The dryer must not be installed in an area where it will be exposed to water and/or weather. If room temperature is below 7º C (45º F), automatic cycles may not shut off.

Maximum slope under entire dryer should not be more than 2.5 cm (1") . If slope is greater than 2.5 cm (1") , install Extended Dryer Feet Kit, Part No. 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level. Floor must be able to support dryer weight of 79.4 kg (175 lbs).

*Opening is the minimum for a closet door.

Louvered doors with equivalent air openings are acceptable.

3

Image 3
Contents Rev a 8528095 Rév a Table of Contents Índice Table des matièresDryer Safety Table of ContentsLocation Requirements Installation RequirementsRecessed Area and Closet Installation Instructions Tools and PartsProduct Dimensions Electrical Requirements26 cm 10-1/4 Left or right side exhaust Recommended Earthing Method Venting RequirementsRigid Metal Vent Vent System LengthMaximum Vent Length 10.2 cm 4 Diameter Exhaust HoodsInstall Ventwork Prepare DryerStand dryer up on cardboard or hardboard Electrical Connection Level and Exhaust the Dryer Technical Specification Check OperationMoving dryer to a new location? Seguridad DE LA Secadora ÍndiceInstrucciones para la instalación empotrada o en clóset Requisitos DE InstalaciónPiezas y herramientas Requisitos de ubicaciónMedidas del producto Requisitos eléctricosMétodo recomendado de conexión a tierra Requisitos de ventilaciónDucto de escape de metal rígido Largo del sistema de ventilaciónLongitud máxima del ducto de escape 1Capotas de ventilación de 10,2 cm 4 de diámetroInstalación de la ventilación Preparación de la secadoraPonga la secadora de pie sobre el cartón o madera dura Conexión eléctrica Nivelación y ventilación de la secadora Verifique el funcionamiento Especificaciones técnicas¿Va a mover la secadora a otro lugar? Table DES Matieres Securite DU SECHE-LINGENe pas sécher darticles qui ont été précédemment Dexécuter Outils nécessaires Exigences DinstallationExigences demplacement Outillage et pièces35.6 Dimensions du produitSpécifications électriques De branchementInstructions DE Liaison a LA Terre Exigences concernant l’évacuationConduit métallique rigide Longueur du système d’évacuationLongueur maximale du conduit Clapets d’évacuation Diamètre de 10,2 cmPréparation du sèche-linge Installation du dispositif d’évacuationRaccordement électrique Réglage de l’aplomb et évacuation du sèche-linge Contrôle du fonctionnement Caractéristiques techniquesRev a 8528095 Rév. a